8. To verify that the device has been installed correctly, enter the following Linux command in
the terminal:
$ sudo lspci -vd 10ee:
If the card is successfully installed and found by the operating system, a message similar to
the one below will be displayed.
This is a sample output for an installed Alveo U250 card:
65:00.0 Processing accelerators: Xilinx Corporation Device 5004
Subsystem: Xilinx Corporation Device 000e
Flags: bus master, fast devsel, latency 0, NUMA node 0
Memory at 380072000000 (64-bit, prefetchable) [size=32M]
Memory at 380074040000 (64-bit, prefetchable) [size=256K]
Capabilities: [40] Power Management version 3
Capabilities: [60] MSI-X: Enable+ Count=32 Masked-
Capabilities: [70] Express Endpoint, MSI 00
Capabilities: [100] Advanced Error Reporting
Capabilities: [1c0] #19
Capabilities: [400] Access Control Services
Capabilities: [410] #15
Capabilities: [480] Vendor Specific Information: ID=0020 Rev=0
Len=010 <?>
Kernel driver in use: xclmgmt
Kernel modules: xclmgmt
Note: If this card has previously been installed, the lspci output will be similar to the one shown in
Running
lspci.
If you do not see a message similar to either of these, see
UG1301 (v1.8) February 5, 2021
Getting Started with Alveo Accelerator Cards
Chapter 3: Card Installation Procedures
Chapter 7:
Troubleshooting.