NAPCO GEMINI GEM-P1632 Programming Instructions Manual page 49

Control panel/communicator
Table of Contents

Advertisement

WI1148B 10/06
Table 1
DATA
RELAY #
ENTRY
blank (•)
NONE
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
Table 2
DATA
TURN OFF
ENTRY
ON AREA
DISARM
blank (•)
NONE
1
Area 1
2
Area 2
3
Area 1 &
Area 2
Table 4
EVENT ID CODES
DATA ENTRIES
OPTION
LEFT
RIGHT
blank (•)
blank (•)
Area 1 Arm
blank (•)
1
Area 2 Arm
blank (•)
8
Zone 1
blank (•)
9
Zone 2
blank (•)
0
Zone 3
blank (•)
B
Zone 4
blank (•)
C
Zone 5
blank (•)
D
Zone 6
blank (•)
E
Zone 7
blank (•)
F
Zone 8
1
blank (•)
Zone 9
1
1
Zone 10
1
2
Zone 11
1
3
Zone 12
1
4
Zone 13
1
5
Zone 14
1
6
Zone 15
1
7
Zone 16
1
8
Zone 17
1
9
Zone 18
1
0
Zone 19
1
B
Zone 20
1
C
Zone 21
1
D
Zone 22
1
E
Zone 23
1
F
Zone 24
2
blank (•)
Zone 25
2
1
Zone 26
2
2
Zone 27
2
3
Zone 28
2
4
Zone 29
2
5
Zone 30
2
6
Zone 31
2
7
Zone 32
* NOTE: Keypad Auxiliary is not to be selected for UL Installations.
NOTE: Keypad Tamper must be enabled in UL installations.
L
NAPCO Security Systems
RELAY EVENT OPTIONS
RELAY #
AREA
See
See
Table 1 below
Table 2 below
(right nibble)
(right nibble)
Table 4 (cont'd)
EVENT ID CODES
DATA ENTRIES
LEFT
RIGHT
3
blank (•)
3
1
3
2
3
3
3
4
3
5
3
6
3
8
3
9
3
0
3
B
3
C
3
D
3
E
4
blank (•)
4
3
4
4
4
5
4
6
4
7
4
D
RF Receiver Trouble (Tamper/Fail)
4
E
4
F
Wireless TX Trouble (LB/Supervisory)
C
8
C
9
D
blank (•)
D
1
D
2
Quickloader Device Control
D
5
General System Alarm
D
8
Area 1 General System Alarm
D
9
Area 2 General System Alarm
F
blank (•)
F
1
F
8
F
9
TIMEOUT
EVENT ID
Enter a Time
See
period, in seconds
Table 4 below
or minutes
OPTION
Area 1 KP Ambush
Area 1 KP Panic
Area 1 KP Fire
Area 1 KP Aux *
Area 1 KP Tamper
Area 1 Fail to Open
Area 1 Fail to Close
Area 2 KP Ambush
Area 2 KP Panic
Area 2 KP Fire
Area 2 KP Aux *
Area 2 KP Tamper
Area 2 Fail to Open
Area 2 Fail to Close
Test Timer
Memory Fail
Low Battery
AC Fail
EZM Tamper
Alarm Supervisory
Wireless TX Tamper
Area 1 Arming AWAY
Area 2 Arming AWAY
Keypad Fail
EZM Fail
Relay Control Group 1
Relay Control Group 2
Entry Relay Area 1
Entry Relay Area 2
X
GEM-P1632 Programming Instructions
COND.
See
Tables 5A & 5B
below
Table 5A
RELAY EVENT
ALARM TYPE OPTIONS
LEFT DATA
ALARM TYPE
TIMEOUT TYPE
blank (•)
Burglary
1
Fire
4
Day Zone
8
Burglary
9
Fire
C
Day Zone
Table 5B
RELAY EVENT ACTIVATION CONDITIONS
RIGHT DATA
OPTIONS
1
Alarm
2
Restore
3
Trouble
4
Trouble Restore
5
Follow Zone
Page 49
Minutes
Minutes
Minutes
Seconds
Seconds
Seconds