AREA BELL C ON TROL OPTI ONS (AD DRESS 14 7 7, 1 47 8 )
Area 1: Pulsed Burg Output Turns Off upon Disarm
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
Area 2: Pulsed Burg Output Turns Off upon Disarm
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
OUTPUT TURNS OFF UPON DISARM:
Select options for the Output. By default, the ability to turn off an output upon disarm is not allowed. For example, the ability to si-
lence an Area 1 or Area 2 output via an Area 1 keypad is not enabled by default. To enable selected area output control, enter the
number (1 or 2) accordingly. For example, if you wish to grant an Area 1 keypad the ability to turn off an Area 2 PGM2 output, en-
ter "2" in Address 1485.
1. Select the desired option by circling
2. Add the data values (ex: F=15=(1+2+4+8) from the selected options. See page 23).
3. Enter in right digit address location. NOTE: Dark shaded data value box shows option not available.
U
4. Press
to save.
X
GEM-P1632 Programming Instructions
LEFT DATA
Pulsed Burg Output
VALUES
Turns Off upon Disarm
)
ADDRESS 1477
(CIRCLE
LEFT DIGIT (SUM
1
OF DATA VALUES)
2
4
8
[Default = blank (•) one (1)]
Pulsed Burg Output
LEFT DATA
VALUES
Turns Off upon Disarm
)
ADDRESS 1478
(CIRCLE
LEFT DIGIT (SUM
1
OF DATA VALUES)
2
4
8
[Default = blank (•) one (1)]
the data values for right digit only (left is not used).
RIGHT DATA
VALUES
RIGHT DIGIT (SUM
OF DATA VALUES)
(1)
RIGHT DATA
VALUES
(CIRCLE
RIGHT DIGIT (SUM
OF DATA VALUES)
(1)
L
WI1148B 10/06
Disarming Area 1
Area 1 Pulsed Burg Output
1
Silenced
Area 2 Pulsed Burg Output
2
Silenced
RESERVED
4
RESERVED
8
Disarming Area 2
)
Area 1 Pulsed Burg Output
1
Silenced
Area 2 Pulsed Burg Output
2
Silenced
RESERVED
4
RESERVED
8
NAPCO Security Systems