AREA BELL C ON TROL OPTI ONS (AD DRESS 14 8 5, 1 48 6 )
Area 1: PGM2 Output Turns Off upon Disarm
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
Area 2: PGM2 Output Turns Off upon Disarm
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
OUTPUT TURNS OFF UPON DISARM:
Select options for the Output. By default, the ability to turn off an output upon disarm is not allowed. For example, the ability to si-
lence an Area 1 or Area 2 output via an Area 1 keypad is not enabled by default. To enable selected area output control, enter the
number (1 or 2) accordingly. For example, if you wish to grant an Area 1 keypad the ability to turn off an Area 2 PGM2 output, en-
ter "2" in Address 1485.
1. Select the desired option by circling
2. Add the data values (ex: F=15=(1+2+4+8) from the selected options. See page 23).
3. Enter in right digit address location. NOTE: Dark shaded data value box shows option not available.
U
4. Press
to save.
X
GEM-P1632 Programming Instructions
LEFT DATA
Turns Off upon Disarm
VALUES
)
ADDRESS 1485
(CIRCLE
LEFT DIGIT (SUM
1
OF DATA VALUES)
2
4
8
[Default = blank (•) one (1)]
LEFT DATA
Turns Off upon Disarm
VALUES
)
ADDRESS 1486
(CIRCLE
LEFT DIGIT (SUM
1
OF DATA VALUES)
2
4
8
[Default = blank (•) one (1)]
the data values for right digit only (left is not used).
PGM2 Output
RIGHT DIGIT (SUM
OF DATA VALUES)
(1)
PGM2 Output
RIGHT DIGIT (SUM
OF DATA VALUES)
(1)
WI1148B 10/06
RIGHT DATA
VALUES
Disarming Area 1
Area 1 PGM2 Burg Output
1
Silenced
Area 2 PGM2 Burg Output
2
Silenced
RESERVED
4
RESERVED
8
RIGHT DATA
VALUES
Disarming Area 2
)
(CIRCLE
Area 1 PGM2 Burg Output
1
Silenced
Area 2 PGM2 Burg Output
2
Silenced
RESERVED
4
RESERVED
8