NAPCO StarLink SLE Series Installation Instructions Manual
NAPCO StarLink SLE Series Installation Instructions Manual

NAPCO StarLink SLE Series Installation Instructions Manual

Dual-path alarm communicators
Hide thumbs Also See for StarLink SLE Series:

Advertisement

R
333 Bayview Avenue, Amityville, New York 11701
For Sales and Repairs, (800) 645-9445
For Technical Service, (800) 645-9440 or visit us at
http://tech.napcosecurity.com/
(Note: Technical Service is for security professionals only)
Publicly traded on NASDAQ
Symbol: NSSC
© NAPCO 2020
INTRODUCTION
The StarLink
LTE Series Dual-Path Commercial / Resi-
dential Fire alarm capture IP communicators are fully su-
pervised, wireless digital two-way subscriber units.
models are compatible with most 12/24VDC alarm control
panels (always adhere to the documentation provided by
the control panel manufacturer). These communicators are
for use as the primary means of communication with the
central station and do not have backup mode capability.
No POTS (Telco Line) connection permitted. Dual Path
Communicators can also be utilized as a Sole Path Cell
Communicator. See WI2140 for programming information.
The following models are available:
SLE-LTEVI-CFBPS & SLE-LTEAI-CFBPS: Commercial /
Residential Fire LTE TCP/IP Communicators in red met-
al housing with SLE-ULPS-R power supply and 16.5V /
20VA transformer mounted inside housing
SLE-LTEVI-CFB & SLE-LTEAI-CFB: Commercial / Resi-
dential Fire LTE TCP/IP Communicators in red metal
housing.
Powered
Aux/Remote Fire Power (no power supply, no trans-
former, rated nominal 12/24VDC input)
The following features are included with models that in-
clude a SLE-ULPS-R power supply:
 Power limited output to the StarLink communicator PC
board 12V input terminals
 Battery connection red and black flying leads
 Monitored battery charging and Active battery test circuits
 StarLink communicator trouble input (from StarLink PC
board PGM1 terminal to detect StarLink communicator
trouble)
 Requires a sealed lead acid min 4AH / max 7AH battery
for minimum 24-hour standby time (max charge current
200mA).
 Trouble relay output (C, N/O and N/C terminals) to
wire to a panel zone dedicated to "Communicator Trou-
ble" (dry contacts). Remove jumper "J2" isolate relay
OUT1 common from ground
 Green AC ON LED visible from the exterior housing
 Yellow TROUBLE LED "D4" on PC board. Flashes sig-
nify:
One flash: AC fail / brownout
Two flashes: Low battery
Three flashes: Charging circuit trouble
Four flashes: StarLink communicator trouble
The housing-mounted transformer (when provided) is
mounted inside its own housing compartment with a re-
placeable UL Listed .5A fast blow primary fuse. 120VAC
connections are to be made by a licensed electrician using
suitable connectors, in accordance with N.E.C. and local
code requirements.
StarLink
SLE Commercial LTEVI & LTEAI Series Dual-Path Alarm Communicators -- Installation Instructions
StarLink™ SLE Commercial
LTEVI & LTEAI Series
Dual-Path Alarm Communicators
INSTALLATION INSTRUCTIONS
directly
from
control
ADDITIONAL COMPONENTS
In addition to the models listed above, the following sub-
assemblies are available:
All
SLE-ULPS-R - Power Supply. Required for installations
where the control panel cannot provide the Auxiliary
power required to operate the StarLink communicator.
Uses a standard 4AH / 12V minimum (7AH maximum,
required with optional Wi-Fi Module) rechargeable bat-
tery to provide communicator standby power. Requires
connection to either the model NAPCO TRF12/T123
(16.5V / 20VA) external plug-in transformer or the chas-
sis-mounted 16.5VAC / 20VA transformer affixed inside
the housing (see wiring diagrams further in this manual).
Note: For models without the SLE-ULPS-R, connect
the communicator terminals 1 and 2 to the control panel
Aux Power terminals (observing polarity).
SLE-WIFI-MODULE - Allows your Napco StarLink
to connect to the Internet by means of a wireless (Wi-Fi)
link, eliminating a wired Ethernet cable connection.
Note: 7AH battery required when using the SLE-
panel
WIFI-MODULE. For more information, see WI2191.
SLE-DLCBL - Download Cable, 6 feet
SLE-ANTEXT30 - Extended antenna with 30 feet of cable
SLE-ANTEXT50 - Extended antenna with 50 feet of cable
SLE-ANTEXT75 - Extended antenna with 75 feet of cable
SLE-ANTEXT100 - Extended antenna with 100 feet of cable
(Any suitable external cellular antenna is permitted by
UL). Always follow the manufacturer's installation in-
structions. Note: Antennas are not Listed by UL.
GEM-Tamperkit - Tamper switches and screws to protect
metal housing (see page 14).
SPECIFICATIONS
The following specifications apply to all StarLink communi-
cator models unless otherwise stated:
Electrical Ratings for 120VAC, 60Hz
For Models with Power Supply
 Input Voltage: 120VAC nominal
 Input Current: 200mA maximum
 Maximum Charging Current: 200mA
AGENCY LISTINGS
 UL 864 Standard For Control Units and Accessories For Fire
Alarm Systems, 10th Edition
 UL 1610 Standard For Central-Station Burglar-Alarm Units
 UL 985 Standard For Household Fire Warning System Units
 UL 1023 Standard For Household Burglar-Alarm System Units
 UL 1076 APOU Proprietary Alarm Systems
 UL 365 APAW Police Connect
 NYC Fire Dept. Certificate of Approval #6317 & 6318
WI2327E.aLF 11/20
device
1

Advertisement

Table of Contents
loading

Summary of Contents for NAPCO StarLink SLE Series

  • Page 1 Requires No POTS (Telco Line) connection permitted. Dual Path connection to either the model NAPCO TRF12/T123 Communicators can also be utilized as a Sole Path Cell (16.5V / 20VA) external plug-in transformer or the chas- Communicator.
  • Page 2: Terminal Descriptions

    Electrical Ratings for +12V / 24V TERMINAL DESCRIPTIONS For Models without Power Supply † Configure all inputs and outputs using the Management  Input Voltage: 10-25VDC regulated (power-limited out- Center screen (located at www.NapcoNOC.com). Located put from Listed control panel Aux/Remote Fire Power). at the bottom of the StarLink communicator PC board, the ...
  • Page 3: Led Descriptions

    TB20: C OUT1: Common. Dry contact Form C relay. during each part of the process (dialing, handshaking, Add shunt to lower two pins of JP1 for wet contacts data transmission, etc.). (connects relay Common to system ground). Relay RED TROUBLE LED rated 30V AC/DC, 500mA.
  • Page 4: Supplying Power

    cation (such as when 24-hour standby time is required for Fire or CO), the SLE-ULPS-R Charger Module accessory must be used to charge an additional battery and to supply the power for the StarLink communicator. See WI2131. Note: The cable modem/router and switch (if any) at the premises requires standby power, therefore a UL 1481 or RED DIAGNOSTIC LED (Labeled "D7") UL 864 Listed UPS must be used at the premises to power...
  • Page 5: Installation Steps

     TB21: N/C OUT1: Wired to the (+) of a zone dedi- cated to monitoring the communicator status. Should STEP 1: ACCOUNT REGISTRATION be programmed on Napco GEMC control panels as Create a new account and register specific StarLink com- Monitor or Supervisory Zone.
  • Page 6 The communicator must also report this trouble to the central station. With NAPCO GEMC control panels, wire S I G N A L S O R I G I N A T E D A T T H E N O C...
  • Page 7 the zone as indicated in the wiring diagrams further in this optionally have front and rear tamper switches installed manual. (GEM-Tamperkit) and wired to the control panel (see For models with the SLE-ULPS-R Power Supply, wire page 14). Note: The tamper switch on the communicator this Power Supply trouble output relay to the two terminals PC board is not used in this housing (but continues to of the control panel zone dedicated to the trouble.
  • Page 8 to the transmitted message 3. When used DACT for Central Station communication, two e. The maximum duration between the initiation of an means of communication are required. The primary chan- alarm signal at the protected premises, transmission of nel shall be telephone line. Cellular or internet communica- the signal, and subsequent display and recording of the tion shall be limited for the secondary means of communi- alarm signal at the Central Station shall not exceed 90...
  • Page 9 (Commercial Fire) SLE-LTEVI-CFBPS & SLE-LTEAI-CFBPS Wiring Diagram SLE-LTEVI-CFBPS & SLE-LTEAI-CFBPS Yellow Green AC Trouble Note: Connect IN2 to a ON LED PC Board panel output used for identifying Telco line cut (this All connections are power limited except AC is the DACT interconnect Mains and battery terminals Power Supply wiring to the radio).
  • Page 10 Wiring Diagram for Generic FACPs with TELCO RJ Sockets (CONTROL PANEL HOUSING) F A C P P C B O A R D TELCO RJ SOCKET (SECONDARY) Optional: When Power Supply SLE-ULPS-R is not used, connect FACP AUX/Remote Fire Power or TELCO RJ SOCKET (PRIMARY) Listed power supply (+12V or +24V) to StarLink terminals 1 and...
  • Page 11 Wiring Diagram for Generic FACPs without TELCO RJ Sockets (CONTROL PANEL HOUSING) F A C P P C B O A R D Optional: When Power Supply SLE-ULPS-R is not used, connect FACP AUX/Remote Fire Power or Listed power supply (+12V or +24V) to StarLink terminals 1 and 2 (observing polarity) PRIMARY TELCO...
  • Page 12 Wiring Diagram for GEMC-32, GEMC-96, GEMC-128 and GEMC-255 Control Panels (CONTROL PANEL HOUSING) Requires all 8 wires in the RJ-45 cable GEMC Control Panel PC Board AUX/Remote Fire PWR Or use a 12V/24V UL Listed monitored power supply To Panel Zone Dedicated to Radio Trouble J7: Remove shunt to...
  • Page 13 NOTES Alternate Telco Line to Alarm Panel Supervision The following wiring and programming method allows an existing FACP to use its two telephone connections (primary and secondary) for supervision and central station reporting through the StarLink SLE-LTEVI-FIRE radio. By removing the JP2 shunt and enabling the feature "Tip/Ring Wiring Fault Report", when any radio trouble is detected, the StarLink radio will remove voltage from the secondary telephone output, triggering the FACP to locally annunciate the Telco trouble and report the trouble to the central station.
  • Page 14 Tamper Switch Mounting Instructions WIRING THE TAMPER SWITCHES Before installation and wiring, the tamper switches (part GEM- Tamperkit) are normally open devices; when placed into the circuit and into operation, they are normally closed devic- Tamper switches protect against the opening of the radio cabi- net door or the removal of the radio enclosure from the wall or other mounting surface.
  • Page 15 UL LISTED ELECTRICAL PULL BOX WITH LISTED OUTLET BOX AND NON-SWITCHED RECEPTACLE ON DEDICATED FIRE ALARM SYSTEM BRANCH CIRCUIT CONDUIT TRANSFORMER OUTPUT WIRING UL LISTED PULL BOX UL LISTED NAPCO TRF12/T123 TRANSFORMER FOR WALL CONNECTION TO SLE CHARGER BOARD UL LISTED SURFACE OR FLUSH MOUNT OUTLET BOX...
  • Page 16: Napco Limited Warranty

    36 months following the date of manufacture. NAPCO In no event shall NAPCO be liable for an amount in excess of NAPCO's will, within said period, at its option, repair or replace any product failing to original selling price of the product, for any loss or damage, whether operate correctly without charge to the original purchaser or user.

Table of Contents