AREA BELL C ON TRO L O PTIONS (ADDRESS 1481, 1482)
Area 1: PGM1 Output Turns Off upon Disarm
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
Area 2: PGM1 Output Turns Off upon Disarm
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
OUTPUT TURNS OFF UPON DISARM:
Select options for the Output. By default, the ability to turn off an output upon disarm is not allowed. For example, the ability to si-
lence an Area 1 or Area 2 output via an Area 1 keypad is not enabled by default. To enable selected area output control, enter the
number (1 or 2) accordingly. For example, if you wish to grant an Area 1 keypad the ability to turn off an Area 2 PGM2 output, enter
"2" in Address 1485.
1. Select the desired option by circling
2. Add the data values (ex: F=15=(1+2+4+8) from the selected options. See page 23).
3. Enter in right digit address location. NOTE: Dark shaded data value box shows option not available.
U
4. Press
to save.
L
NAPCO Security Systems
LEFT DATA
PGM1 Output Turns Off upon Disarm
VALUES
ADDRESS 1481
)
(CIRCLE
LEFT DIGIT (SUM
1
OF DATA VALUES)
2
4
8
[Default = blank (•) one (1)]
LEFT DATA
PGM1 Output Turns Off upon Disarm
VALUES
ADDRESS 1482
)
(CIRCLE
LEFT DIGIT (SUM
1
OF DATA VALUES)
2
4
8
[Default = blank (•) one (1)]
the data values for right digit only (left is not used).
RIGHT DATA
VALUES
(CIRCLE
RIGHT DIGIT (SUM
OF DATA VALUES)
(1)
RIGHT DATA
VALUES
(CIRCLE
RIGHT DIGIT (SUM
OF DATA VALUES)
(1)
X
GEM-P1632 Programming Instructions
Page 39
Disarming Area 1
)
Area 1 PGM1 Output Silenced
1
Area 2 PGM1 Output Silenced
2
RESERVED
4
RESERVED
8
Disarming Area 2
)
Area 1 PGM1 Output Silenced
1
Area 2 PGM1 Output Silenced
2
RESERVED
4
RESERVED
8