6.3 Jumper
Jumper
Description
JR4
Overtravel reduction.
Reduces the overtravel distance for the
door wing.
JR6
Application type.
NIO
Electronic antifreeze system. Maintains
motor function even at low ambient tem-
peratures.
NOTE: for correct operation, the control
panel must be exposed to the same am-
bient temperature as the motors.
JR10
Maximum power at start.
OM
Automation type.
D5
Step-by-step sequence.
S5
Step-by-step sequence stop duration.
JT
Closing operation time.
EO
Electric lock function.
SO
Reversal safety switch func-tion.
6.4 Signals
LED
On
24 V power supply
POWER
Indicates that at least one of the safety contacts is open.
SA
Activated at every command and adjustment to the dip-switch
IN
and jumper.
Indicates that the 0-11 limit switch contact is open.
11
Indicates that the 0-12 limit switch contact is open.
12
OFF
Disabled.
NOTE: set JR4=OFF is the motor is equip-
ped with an electric brake.
Sliding gate.
Enabled.
ATTENTION: do not use with LOGICMJ.
Disabled.
The motor starts with the voltage set with RF.
One motor automation (M1 only).
Open-stop-close-stop-open.
Permanent.
(Automatic closing disabled).
Set with TM+4 s.
NOTE: set JT=OFF with hydraulic or friction
gearmotor.
Powered with automation closed.
With automation stopped and contact 41-8
open, opening operations are permitted.
Flashing
Operations count performed (only when control panel is switched
on):
= 1000 operations
= 10000 operations
8
ON
Enabled.
NOTE: preferably set JR4=ON if the door
wing performs an excessive overtravel.
Other applications.
Disabled.
Enabled.
The motor starts at maximum power for 1 s.
Automation with two independent motors.
Open-stop-close-open.
Temporary.
(Automatic closing enabled).
Automatic.
Powered for 1 s at the beginning of the
opening operation.
With automation stopped and 41-8 open, all
operations are disabled.
/
Safety test failure (terminal 41).
/
/
/