FOR UP-AND-OVER GARAGE DOOR OPENER:
posizionare il Dip Switch B N°1= ON
Photocells stop motion in opening
Radio does not reverse in opening
Automatic closure
Pre-flashing in service
Step-by-step radio
Blank
mode
Deadman Mode
Blank
DSA photocell transmitter checking, if connected to dedicated terminals
ELECTRICAL CONNECTIONS FOR UP-AND-OVER DOOR OPENING - Dip Switch B n°1=ON
Accessory
Safety edge:
Photocells:
Key-operated
switch:
Radio contact
step-by-step:
Limit switch:
XE
X
Blank
see SAFETY EDGE connections
see SAFETY EDGE connections
Flashing light off during pause
Re-closes during Opening and during pause after passage on the
Photocells
Run Time memory enabled for very frequent cycling
Electrical connections
1 2
The safety edge permits inversion of direction for a short
section of travel, stopping the gate: with DIP A No. 9=ON.
In both travel directions
1 2
All NC contacts of
safety accessories
such as Photocells
NC
(receivers) must be
connected in series
NC
with terminals 1 and 2
3 4 5 6
NO and NC contacts to connect to the
respective terminals in the key- switches
or the push-button panels.
NC
All possible configurations are attached
to the related control accessories.
by connecting any NO contact across the two
terminals, the following can be achieved by
3
7
each pulsing:
- Opening only:
- inversion of direction with each impulse
- Step-by-step: Open-Stop-Close-Stop
- During opening no new command is
accepted. During dwell or closing, each new
command stops and reverses travel
direction.
8 9 10
then bridge inputs 8 and 10 with
common 9
UNIVERSAL ELECTRONIC CONTROL BOXES
230V 50/60Hz SINGLE-PHASE
Dip-Switches and LED signals of the various functions
12 13
n°1 radio receiver
n°2 pairs photocells
if the limit switches
DIP-SWITCH - B
ON
OFF
1
2 3 4
DIP-SWITCH - A
ON
OFF
1 2 3 4 5 6 7 8 9 10 11 12
DIP-SWITCH - B
ON
OFF
1 2 3 4
DIP-SWITCH-A N°8 E N°9:
ON: Increase time during inversion
OFF: Increase time during inversion
8
ON: Inversion of direction with safety edge
OFF: No inversion of direction.
9
L2 ON= no obstacle present, turns off with
obstacle present
DIP-SWITCH-A N° 1:
ON: stop travel in opening and reverse in
closing once cleared from obstacle
OFF: no stop in opening and reverse in closing in
1
case of obstacle
L3 Acceso= no obstacle. It goes off in case
of obstacle.
L4 OFF= no OPEN contact, turns on with
every open impulse
L5 OFF= no CLOSE contact, turns on with
every close impulse
L6 ON= STOP contact closed, turns off with
every stop contact
DIP-SWITCH-A N°2 and N°5:
ON:during opening does not reverse and does
not stop
2
OFF: during opening always stop and reverses
ON:Step-by-step with intermediate stop
OFF: reverses movement by every radio impulse
5
L7 OFF= no RADIO contact, turns on with
every radio contact impulse
L8 ON= off when gate closed
L9 ON= off with gate open