Не закрываются ворота после открытия
1 comments:
Mr. Anderson
September 3, 2025
The Fadini COMBI 740 gates may not close after opening if the semi-automatic function is set to OFF. In this case, the system does not close automatically after opening. Additionally, if there is an obstacle detected by the photocells during closing, the gate will stop or change direction and not complete the closing cycle.
This answer is automatically generated
david
June 9, 2025
My Combi 740 gates have no power to the motor, it looks like a fuse somewhere, what do you think?
1 comments:
Mr. Anderson
August 17, 2025
Possible causes of no power to the motor in a Fadini Combi 740 gate include:
1. No mains power supply (230V 50Hz) connected to the motor. 2. Faulty or missing 12.5 µF capacitor. 3. A blown fuse in the power supply circuit (e.g., fuse F4 or F3). 4. Incorrect wiring connections according to the diagram in Pic. 21. 5. Faulty control board or relay not supplying power to the motor.
Page 1
COMBI 740 Oil-hydraulic operator for swinging gates Below ground Version with two-way locking device Version with brake in open/close cycles Version with 110° and 175° shaft rotation Instruction manual...
Page 2
COMBI 740 CUTAWAY GENERAL VIEW ELECTRIC MOTOR HYDRAULIC JACK LEFT-HAND PISTON JACK END CAP LEFT-HAND CYLINDER DAMPENING DAMPENING LINER DEVICE ADJUSTMENT VALVE COVER SAFETY PRESSURE VALVE “OPEN” TWO-WAY LOCKING SAFETY VALVE PRESSURE ASSEMBLY VALVE “CLOSE” TWO-WAY LOCKING VALVE ASSEMBLY RELEASING...
Page 3
JACK ASSEMBLY AND MOVEMENT SYSTEM CENTRAL RACK BLOCK COVER PISTON BEARING TOOTHED TIE ROD MOTOR PUMP JACK CYLINDER LINER RIGHT-HAND JACK MAIN SHAFT JOINING PART END CAP DAMPENING ADJUSTMENT ELBOW JOINT OIL RESERVOIR CABLE WIRE PLUG CONNECTOR CONNECTORS EARTH PHASE PHASE COMMON OIL RESERVOIR...
Page 4
INSTRUCTIONS FOR THE INSTALLATION OF COMBI 740, ELECTRO-HYDRAULIC, BELOW GROUND, ALL-IN-ONE, WITH ANTI-CRUSH SYSTEM. It is recommended to keep to these instructions to install the equipment in the correct way to get a perfect working system. Electro- hydraulic operator consisting of a jack combined to a motor pump unit for the operation of swinging gates. All-in-one in a specially designed enclosure to be sunk in the ground under the gates as shown in picture No.
Page 5
SOAK AWAY SOAKAWAY PIPE TO BE CONNECTED TO THE STORM DRAIN BRICKWORK FOUNDATIONS PIC. 4 TOP HINGE FIXING SCREWS MINIMUM DISTANCE ALLOWED SHAFT FITTING COLLAR 702/5 COMBI 740 CABLE OUTLET SOAKAWAY PIPE DISTANCE GRAVEL PIC. 5 CONCRETE DISTANCE ITEM No.
Page 6
SHAFT FITTING COLLAR PIC. 8 BOX SPANNER LONG BOLTS COMBI 740 Once satisfied that everything has been done as described so far, make sure that the two units are mounted on the correct side of the gate, view from inside the property: the unit marked “D” on the right- hand side and “S”...
Page 7
Anti-crush safety is ensured by the pressure valves which allow for a very fine adjustment of the required pushing power depending on the gate size and weight; after setting no further adjustment is required thanks to their precise design. Also they are adequately protected to prevent misuse.
Page 8
Should the model with the dampening device be required to install JUNCTION BOX adjustment in the open and close cycles is by means of a screw on the top of the jack end cap: with a screwdriver give one turn clockwise.
Page 9
ONE PULSE OPENS ONE GATE LEAF ONLY NOTE WELL: THIS PANEL IS TESTED TO OPERATE GATES ONLY THROUGH FADINI ACCESSORIES. NO WARRANTY IS ACKNOWLEDGED BY THE MANUFACTURER IN CASE THAT PULSE TWICE CONSECUTIVELY OTHER ACCESSORIES ARE USED OR NON CONFORMING...
Page 10
MANUAL TEST FOR COMBI 740 CONNECTION TWO MOVES TO POSITION THREE. THIS SHOULD REVERSE GATE OPERATION 230 V 50 Hz FIXED CONNECTION BLUE CONDENSER 12,5 F YELLOW/GREEN CONNECT THE PIC. 20 ENCLOSURE EARTH WIRE SPECIAL VERSIONS FLOW REGULATORS FOR COMBI 740...
Page 11
COMBI 740 TECHNICAL SPECIFICATIONS A The combined motor and jack of the COMBI 740 employs the latest technology with a quiet-running steel lobe pump at its heart, creating and holding greater pressures for hydraulic locking and drive than most other underground gate operators.
Page 12
- The electrical equipment must be properly earthed. Meccanica Fadini recommends the control panel ELPRO 13 CEI to achieve an installation that is in conformity to the existing safety * Best performance can only be achieved by keeping to these standards as illustrated in our chart.
Need help?
Do you have a question about the COMBI 740 and is the answer not in the manual?
Questions and answers
Не закрываются ворота после открытия
The Fadini COMBI 740 gates may not close after opening if the semi-automatic function is set to OFF. In this case, the system does not close automatically after opening. Additionally, if there is an obstacle detected by the photocells during closing, the gate will stop or change direction and not complete the closing cycle.
This answer is automatically generated
My Combi 740 gates have no power to the motor, it looks like a fuse somewhere, what do you think?
Possible causes of no power to the motor in a Fadini Combi 740 gate include:
1. No mains power supply (230V 50Hz) connected to the motor.
2. Faulty or missing 12.5 µF capacitor.
3. A blown fuse in the power supply circuit (e.g., fuse F4 or F3).
4. Incorrect wiring connections according to the diagram in Pic. 21.
5. Faulty control board or relay not supplying power to the motor.
Each of these should be checked systematically.
This answer is automatically generated