FOR SLIDING GATES WITH LIMIT SWITCHES:
position Dip Switch B No1= ON
Photocells stop during opening
Radio does not reverse during opening
Automatic closure
Pre-flashing operational
Step-by-step radio
Pedestrian service
Deadman mode
DSA photocell transmitter control if connected to dedicated terminals
Accessory
Safety edge:
Photocells:
Key-operated
switch:
Radio Contact:
(step-by-step mode)
Limit switches:
XE
UNIVERSAL ELECTRONIC CONTROL BOXES
230V 50/60Hz SINGLE-PHASE
No function
= see SAFETY EDGE connections
= see SAFETY EDGE connections
Flashing light off during pause
Closes during Opening and during pause after passage on the
Photocells
mode
Electrical connections
1 2
NC contact for safety edge to allow travel reversing for a short
bit in both cycles and gate stopping: with
1 2
All NC contacts of
safety accessories
such as Photocells
NC
(receivers) must be
connected in series
NC
with terminals 1 and 2
NO and NC contacts to connect to
3 4 5 6
the respective terminals on the
selector switches or the push-button
panel.
NC
All possible configurations are
attached to the related control
accessories.
connecting any NO contact across the two
terminals generates, with each impulse:
3
7
- Opening only:
- inversion of direction with each impulse
- Step-by-step: Open-Stop-Close-Stop
- During opening no new command is
accepted. During dwell or closing, each new
command stops and reverses travel
direction.
8 9 10
then bridge inputs 8 - 9 - 10
Dip-Switches and LED signals of the various functions
12 13
max. load:
n°1 radio receiver
n°2 pairs photocells
if the limit switches
DIP-SWITCH - B
ON
OFF
2 3 4
1
DIP-SWITCH - A
ON
OFF
1 2 3 4 5 6 7 8 9 10 11 12
DIP-SWITCH - B
ON
OFF
1 2 3 4
DIP-SWITCH-A N°8 and N°9:
Increase time during inversion
No increase of inversion time
8
Inversion of direction with safety edge
No inversion of direction
9
= no obstacle detected, turns off in
L2
case of obstacle
DIP-SWITCH-A N° 1:
ON: stop in Opening and reverse in
Closing once cleared from obstacle
OFF: no stop in opening, reverse on closing in
1
case of obstacle
L3 ON= no obstacle. It switches off in case
of obstacle
L4 OFF= no OPEN contact, turns on with
every open impulse
L5 OFF= no CLOSE contact, turns on with
every close impulse
L6 ON= STOP contact closed, turns off with
every stop impulse
DIP-SWITCH-A N°2 and N°5:
ON: no stop and no reversing in opening
2
OFF: during opening always stop and reverse
ON:Step-by-step with intermediate stop
OFF: reverse movement by every radio impulse
5
L7 OFF= no RADIO contact, turns on with
every radio contact impulse
L8 ON= off when gate closed
L9 ON= off with gate open