FOR SWINGING GATE OPENERS:
position Dip Switch B No.1= OFF
Photocells stop gate during opening
Radio does not reverse in opening
Automatic closure
Pre-flashing operational
Step-by-step radio
Pedestrian service
Deadman function
reverse direction by means of the safety devices in the operation area
DSA control of the photocell transmitters if conneced to the dedicated terminals
Accessory
2nd pair of
Photocells:
installed internally
1° pair Photocells:
installed externally
Key-operated
switch
Radio contact
(step-by-step mode):
Limit Switches: if not
fitted, link out the
terminals or use
terminals 9 and 10 for
the function reverse
direction during
opening (described on
page 18) (*)
page 16
X
XE
Stroke Reversing Pulse on Opening
No wing delay during opening. Motors start together
Enables input of the 2nd pair of photocells
Flashing light off during pause
Re-closes in Opening and Dwell time after crossing the
photocells
are needed
mode
Electrical connections
1 2
12 13
With
stay stopped as long as the photocells are obstructed.
- In opening cycle: obstacle removed, gates go on opening
- In closing cycle: obstacle removed, gate travel reversed
1 2
All NC contacts of
safety accessories
such as Photocells
NC
(receivers) must be
connected in series
NC
with terminals 1 and 2
3 4 5 6
NO and NC contacts to connect to the
respective terminals on the selector
switches or the push-button panel.
NC
All possible configurations are attached
to the related control accessories.
connecting any NO contact across the two
terminals generates, with each impulse:
3
7
- Opening only:
- inversion of direction with each impulse
- Step-by-step: Open-Stop-Close-Stop
- During opening no new command is
accepted. During dwell or closing, each new
command stops and reverses travel
direction.
8 9 10
then bridge inputs 8 and 10 with common 9 .
The terminals 9 and 10 also provide inputs
for the NC contact on opening: if activated
during the opening cycle, gate travel is
reversed for a short distance (see
paragraph Functions on page 18)
UNIVERSAL ELECTRONIC CONTROL BOXES
230V 50/60Hz SINGLE-PHASE
Memory of time settings when frequent operations
max. load:
n°1 radio receiver
n°2 pairs photocells
The gates
12 13
n°1 radio receiver
n°2 pairs photocells
if the limit switches
DIP-SWITCH - B
ON
OFF
1
2 3 4
DIP-SWITCH - A
ON
OFF
1 2 3 4 5 6 7 8 9 10 11 12
DIP-SWITCH - B
ON
OFF
1 2 3 4
Dip-Switches and LED signals of the various functions
DIP-SWITCH-A N°9:
Photocell 2nd pair enabled
No photocell 2nd pair used
9
= no obstacle present, turns off with
L2
obstacle present
DIP-SWITCH-A N° 1:
ON: stop gate in opening and reverse in
closing when cleared
OFF: no stop in opening and reverse in
1
closing when obstructed
L3 ON= no obstacle. It goes off in case
of obstacle
L4 OFF= no OPEN contact, turns on with
every open impulse
L5 OFF= no CLOSE contact, turns on with
every close impulse
L6 ON= STOP contact closed, turns off with
every stop impulse
DIP-SWITCH-A N°2 and N°5:
ON:during opening does not reverse and does
not stop
2
OFF: during opening always stop and reverses
ON:Step-by-step with intermediate stop
OFF: Reverses movement by radio impulse
5
L7 OFF= no RADIO contact, turns on with
every radio contact impulse
L8 ON= off when gate closed
L9 ON= off with gate open