: The electronic control boxes ELPRO X and ELPRO XE have been designed and developed as a solution for those installation engineers
requiring an universal electronic system for any kind of automatic gate to be serviced. It is suitable also for sliding gate operators fitted with limit switches,
single or double swinging gate operators fitted with pressure valves for ELPRO X, and electromechanical operators for ELPRO XE in that it is fitted with torque
control selector, and up-and-over garage doors with 1 or 2 motors, with or without limit switches. ELPRO X and ELPRO XE XE units work with single-phase
230V 50/60 Hz power supply and comply with 2006/95 CE Low Voltage safety regulations and 2004/108/CE & 92/31 CEE Electromagnetic Compatibility
regulations. Installation is recommended to be done by qualified technicians in accordance with existing safety regulations. The Manufacturer shall
not be responsible for improper use of the control boxes and also reserves the right to modify and update the control box at any time.
- The Control Box must be installed in a dry and protected place. It has holes for fastening to a universal FADINI container or to a standard market
electrical box.
- Make sure that the power supply to the electronic control box is 230V ÷ 10%
- Make sure that the power supply to the electrical motor is 230V ÷10%
- Increase wire cross section when distances are greater than 50 meters.
- Install a type 0.03A high sensitivity Ground Fault Switch on the power supply to the control box.
- Power supply, Electrical motor, Flashing light: use 1.5 mm2 cross section wires for distances up to 50 m.
- Limit switch, Photocells, Push-button panels and accessories: use 1 mm2 cross section wires
- If the Photocells are not used then make a bridge across terminals 1 and 2 and all the inputs with NC contacts
- If no Push-button panel is used make a bridge across terminals 3 and 6
- The Open/Close Work Time Trimmer setting must always be greater than the actual travel time of the gate
NOTE: For applications such as turn on lights, video cameras, etc., use Static Switches to avoid generating noise in the microprocesso
:
= 230V grid voltage Present and fuses F1, F2, F3 (F4 only for Elpro X)
= 2nd pair of Photocells or Safety Edge, no obstacle present
= 1st pair of Photocells, no obstacle detected
= Open, turns on with open command impulse
= Close, turns on with close command impulse
= Stop, turns off with stop command impulse
= Radio, turns on with every impulse from the transmitter and radio contact
= Close limit switch, off with gate closed. On during movement and when gate is open on the opening limit switch
= Open limit switch, off with gate open. On during movement and when gate is closed on the closure limit switch
- Make sure that the electronic control box is powered at 230V ÷10%
- Make sure that the Electrical Motor is powered at 230V ÷ 10%
- Check all the fuses
- Check that the Photocells have closed contacts
- Check that there is no voltage drop between the Elpro Control Box and the Electrical Motor
- Adjust the motor power Selector switch depending on the weight and the wing
- Check all the NC contacts of the electronic board
page 12
XE
29
30
OUTPUT
TIME
DIP-SWITCH - A
1 2 3 4 5 6 7 8 9 10 11 12
MICROPROCESSOR
VERSION 03
L4
L5
L3
L6
L7
5
6
7
8
9
10 11 12 13 14 15
UNIVERSAL ELECTRONIC CONTROL BOXES
230V 50/60Hz SINGLE-PHASE
F3=2A
24V low
voltage
protection
-
CLOSING
-
OPENING:
DIP-SWITCH - B
ON
OFF
C1
1 2 3 4
Capacitor
M1Motor
L9
L8
16 17 18 19 20 21 22 23
16
17
M1
:
F4=630mA
from mains
TRANSFORMER
C2
Capacitor
M2Motor
F1=5A
mains fuses
F1=5A main
fuses
24
19
20
21
22
23
24
18
M2
meccanica
FADINI
SELECTING SWITCH
only for ELPRO XE
230V MAX 100W
Turns on when the
gate starts moving
and remains on for a
25
25