Motorola MOTOwi4 Canopy 30 User Manual page 106

Backhaul
Table of Contents

Advertisement

1. There is no power reaching the ODU because of a wiring fault
2. The ODU is faulty
3. The PIDU is faulty
4. The Ethernet network side is faulty
Look at the following table to check the LED response for power up, disconnect the power and
reapply and note what happens.
Differentiating between 1--3 and 4 can be achieved by removing the power for 1 second. Watch
the Ethernet indicator for 1 minute, if it never flashes then the problem is 1—3. Take the jumper
(J906) out of the 30/60 Mbps PIDU and check the current taken by the ODU. This should be
300mA to 1A when starting through to running normally.
If the Ethernet indicator flashes to begin with but then stops flashing then ODU is powered and
software loaded but Ethernet connectivity has been lost between the ODU and the users
connected equipment. All Ethernet connections should be rechecked.
Power Indoor Unit LED check chart:
Mode
No Power
Applied
Power Applied
Valid Ethernet
Link and no
traffic
Valid Ethernet
Link with traffic
While Reset
Switch Pressed
Reset Switch
Pressed and
released within
10 seconds
during normal
operation
Reset Switch
Pressed and
held for > 20
seconds during
normal
Issue 3.1, July 2006
Green
Yellow LED No Ethernet
LED
Cable Connected
Off
Off
Will flash once per second
regularly approximately 16
On
seconds after power
applied for 10 seconds then
will go out and stay out
On
N/A
On
N/A
On
Off
On
Off
Off while switch pressed.
One second after release, flashes twice per second
On
regularly for 10 seconds, then erases non-volatile
configuration data and resets. The erasure will reset the
entire unit's configuration apart from the last known
Yellow LED
Ethernet Cable Connected
between PIDU and
NIC/Switch/Hub
Off
Will flash once per second
regularly approximately 16
seconds after power applied
for 10 seconds then operate
as Ethernet Link/Activity LED
Will be on solid for a valid
link.
Will be on solid, but will blink
randomly as traffic passes
through
Off
Off while switch pressed but
returns to LINK/Activity state
when released. No reset will
take place