Site Planning  
6.1
SITE SELECTION CRITERIA  
The following are guidelines for selecting the installation location of the 30/60 Mbps Backhaul
ODU and 30/60 Mbps PIDU.
6.1.1
ODU
Site Selection  
 
When selecting a site for the ODU the following should be taken into consideration:
That it is not possible for people to stand or walk inadvertently in front of the antenna.
Height and location to achieve the best radio path
Height in relation to other objects with regard to lightning strikes
Protection from the weather
Aesthetics and planning permission issues
Distance from 30/60 Mbps PIDU and connected equipment (Maximum cable run ODU to
connected equipment is 328 ft (100m)
Distance from the 30/60 Mbps PIDU to the ODU (Maximum cable run 30/60 Mbps PIDU
to ODU is 328 ft (100m) minus the length of the cable from the 30/60 Mbps PIDU to the
connected equipment)
6.1.2
30/60 Mbps PIDU
When selecting a site for the 30/60 Mbps PIDU the following should be taken into
consideration:
Availability of a AC mains electricity supply
Accessibility for viewing status indicators and pressing reset switch (See Section 3.1.2
"The 30/60 Power Indoor Unit (PIDU)" and Section 9 "Fault Finding"
Distance from ODU and connected equipment (Maximum cable run ODU to connected
equipment is 328 ft (100m)
Distance from the ODU to the 30/60 Mbps PIDU (Maximum cable run ODU to 30/60 Mbps
PIDU is 328 ft (100m) minus the length of the cable from the 30/60 Mbps PIDU to the
connected equipment)
Issue 3.1, July 2006
Site Selection  
 
Page 33 of 162