Ricoh Pro C9100 Operating Instructions Manual page 159

Hide thumbs Also See for Pro C9100:
Table of Contents

Advertisement

Example of a log file
"1.0.0"
"ExecType", "Date", "SerialNo",PnP", "Model", "Destination","IP","Host","Storage","FileNam
e","FileID","TotalItem","NumOfOkItem","ResultCode","ResultName","Identifier"
"IMPORT"
"20XX-07-05T15:29:16+09:00"
"3C35-7M0014"
"Brand Name"
"Product Name"
"0"
"10"
"10.250.155.125"
"RNP00267332582D"
"SD"
"20XX07051519563C35-710220.csv"
"20XX07051519563C35-710220"
"
0"
"
0"
" 2"
"INVALID REQUEST"
"TargetID","ModuleID","PrefID","Item","NgCode","NgName"
If you cannot resolve the problem or do not know how to resolve it after checking the code, write down
the error log entry, and then contact your service representative.
ResultCode
2 (INVALID REQUEST)
4 (INVALID OUTPUT
DIR)
7 (MODULE ERROR)
8 (DISK FULL)
9 (DEVICE ERROR)
Cause
A file import was
attempted between
different models or
machines with different
device configurations.
Failed to write the device
information to the
destination device.
An unexpected error
occurred during an
import or export.
The available storage
space on the external
medium is insufficient.
Failed to write or read
the log file.
Managing Device Information
CJD023
Solutions
Import files exported from the same model with
the same device configurations.
Check whether the destination device is
operating normally.
Turn the power off and then back on, and then
try the operation again. If the error persists,
contact your service representative.
Perform the operation again after making sure
there is enough storage space.
Check whether the path to the folder for storing
the file or the folder in which the file is stored is
unavailable.
157