Type Plate; Construction; Installation And Operation; Installing The Diaphragm Valve - GEM CleanStar C60 HPW Installation, Operating And Maintenance Instruction

Diaphragm valves
Table of Contents

Advertisement

Available languages

Available languages

9.1

Type plate

Device version
Design in accordance with order data
12103529 I 0001
Traceability number
Item number
The month of manufacture is encoded in
the traceability number and can be obtained
from GEMÜ.
The product was manufactured in Germany.

10 Construction

Optical position indicator
A
1
Mounting base
with flexible slots
Construction
1
Valve body
A
Actuator
DANGER
Do not open the actuator!
® Risk of severe injury or death!
® Manufacturer's warranty will be voided.
C60
Device-specific data
Serial number
Control medium
connector 4
Control medium
connector 2
Central union nut
Tube / pipe
connections
Leak detection port /
fitting connection for
a leakage sensor
36 / 48
CAUTION
Do not disassemble valve body and
actuator!
® Danger of leakage or defect!
® Manufacturer's warranty will be voided.

11 Installation and operation

Prior to installation:
Ensure that valve body and diaphragm
G
material are appropriate and compatible
to handle the working medium.
Check the suitability prior to the
G
installation.
See chapter 6 "Technical data".
11.1 Installing the
diaphragm valve
WARNING
The equipment is subject to pressure!
® Risk of severe injury or death!
Only work on depressurized plant.
G
WARNING
Corrosive chemicals!
® Risk of caustic burns!
Wear appropriate personal
G
protective gear when
installing.
Flush and rinse contaminated
G
installations as necessary.
CAUTION
Hot plant components!
® Risk of burns!
Only work on plant that has
G
cooled down.
CAUTION
Never use the valve as a step or an aid
for climbing!
® This entails the risk of slipping-off or
damaging the valve.

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Cleanstar c60 hpsCleanstar c60 pvdf

Table of Contents