9.1
Type plate
Device version
Design in accordance with order data
12103529 I 0001
Traceability number
Item number
The month of manufacture is encoded in
the traceability number and can be obtained
from GEMÜ.
The product was manufactured in Germany.
10 Construction
Optical position indicator
A
1
Mounting base
with flexible slots
Construction
1
Valve body
A
Actuator
DANGER
Do not open the actuator!
® Risk of severe injury or death!
® Manufacturer's warranty will be voided.
C60
Device-specific data
Serial number
Control medium
connector 4
Control medium
connector 2
Central union nut
Tube / pipe
connections
Leak detection port /
fitting connection for
a leakage sensor
36 / 48
CAUTION
Do not disassemble valve body and
actuator!
® Danger of leakage or defect!
® Manufacturer's warranty will be voided.
11 Installation and operation
Prior to installation:
Ensure that valve body and diaphragm
G
material are appropriate and compatible
to handle the working medium.
Check the suitability prior to the
G
installation.
See chapter 6 "Technical data".
11.1 Installing the
diaphragm valve
WARNING
The equipment is subject to pressure!
® Risk of severe injury or death!
Only work on depressurized plant.
G
WARNING
Corrosive chemicals!
® Risk of caustic burns!
Wear appropriate personal
G
protective gear when
installing.
Flush and rinse contaminated
G
installations as necessary.
CAUTION
Hot plant components!
® Risk of burns!
Only work on plant that has
G
cooled down.
CAUTION
Never use the valve as a step or an aid
for climbing!
® This entails the risk of slipping-off or
damaging the valve.