Adjusting The Current Limiter; Setting The Dip Switches - Webasto Unite Operating And Installation Instructions

Table of Contents

Advertisement

6 | Installation and electrical connection
Pos.
Description
1
Data cable gland
2
Data cable
3
Wrench
Proceed as follows:
1.
Insert the cables (2) into the unit.
2.
Tighten the cable glands (1) using the wrench (3)
6.6

Adjusting the current limiter

NOTE
DIP-switch settings
DIP-switch settings are optional. All settings can be
changed by using the Setup App, or the web configura-
tion interface (see Unite Configuration Interface).
u
The most recent made setting will always be ap-
plied.
u
The current setting is shown in the web configura-
tion interface.
1
1
Rotary switch current limiter settings
The charging station has a current limiter (rotary switch) on its
mainboard. This switch sets the charging station's current and
power limit. To change the settings, use a flathead screwdriver
to gently adjust the arrow in the centre of the rotary switch by
changing its position to the required-current rate. For rate de-
tails, see the table Current limiter positions.
Switch
Phase
position
0
1-phase
1
2
3
4
5
6
7
10 / 26
1
2
3
1
Current limit Value (22
kW)
10 A
13 A
16 A
20 A
25 A
30 A
32 A
X
X
Switch
Phase
position
8
3-phase
9
A
B
C
D
E
F
Required circuit breaker on AC mains
Charging Station
Current Limiter
Setting
10 A
13 A
16 A
20 A
25 A
30 A
6.7

Setting the DIP switches

1
Reserved
2
Enable Potential free contact/Load shedding
3
Locked Cable Function (only for socket models)
4, 5, 6
Power Optimizer (requires optional accessories)
NOTE
DIP-switch settings
DIP-switch settings are optional. All settings can be
changed by using the Setup App, or the web configura-
tion interface (see Unite Configuration Interface).
u
The most recent made setting will always be ap-
plied.
u
The current setting is shown in the web configura-
tion interface.
6.7.1
Enable Potential free contact/Load
shedding
Your charging station can be controlled with external potential-
free contacts (on/off function) for integration of the charging
station into:
l car park automation systems
l energy supplier ripple control devices
l timer switches
l photovoltaic inverters
l auxiliary load control switches
l external key lock switches
l etc.
Current limit Value (22
kW)
10 A
13 A
16 A
20 A
25 A
30 A
32 A
X
X
C-Curve MCB
(miniature circuit
breaker)
13 A
16 A
20 A
25 A
32 A
40 A
ON
1
2
3
4
5
6
5111966A ISI Webasto Unite (EN)