Turbofiller Rinsing - Hardi ALPHA EVO EcoDrive DELTA FORCE 5100 Instruction Book

Table of Contents

Advertisement

7. Flush the TurboFiller with clean water from the rinsing tank or from an external tank by shifting to suction. The
TurboFiller suction valve must be open for at least 20 seconds after the rinse water is no longer visible in the hopper,
in order to completely empty the transfer hoses into the main tank.
μ
ATTENTION! If not flushed with clean water, the hopper rinsing device uses spray liquid for rinsing the hopper!
Cleaning the TurboFiller must always be done, when the spray job is ended, and together with cleaning the entire
sprayer. A cleaning after the last filling, and before spraying, does not ensure a clean TurboFiller!
8. Close TurboFiller suction valve, when the hopper has been rinsed. Close the lid.
9. If closed, turn the agitation valve towards "agitation".
10. When the spray liquid is well agitated, turn handle of the pressure
SmartValve towards "spraying" position. The agitation continues
during spraying of the crop.
μ
ATTENTION! If foaming is a problem, turn down the agitation.
Agitation Before Resuming a Spray Job
If a spray job has been interrupted for a while, severe sedimentation may occur depending on the chemicals being used.
Before resuming the spray job, it might be necessary to agitate sediment material.
1. Turn the handle at the suction valve towards "Suction from main
tank". Turn the pressure SmartValve towards "Pressure
draining/TurboFiller"an unused function closed position and turn
the agitation valve towards "Agitation". Other valves are closed.
2. Engage the pump and set PTO speed to max. 540 r.p.m.
3. Agitation has started and should be continued for at least 10
minutes.
4. The spray job can now be resumed. Turn pressure Smartvalve
towards "Spraying" and start spraying.
DANGER! Before turning Pressure SmartValve to "Pressure draining/TurboFiller" it is very important to be sure that the
quick coupler lid is correct and completely mounted to the filling stud into its locked position. Failure to do so may
cause risk of contamination and injury from quick coupler lid being "shot" off when pressurized! If not possible to
mount lid completely, lubricate the rubber seal and the grip hooks.

TurboFiller Rinsing

÷
NOTE! It is important to suck from the rising tank or an external
tank with clean water.
Rinse the TurboFiller and chemical containers as follows:
Cleaning empty containers - TurboFiller lid is open
1. Put container over the rotating flushing nozzle in the middle of the
TurboFiller, so that the nozzle is inside the container.
5 - Operation
!
127

Advertisement

Table of Contents
loading