Hardi ALPHA EVO EcoDrive DELTA FORCE 5100 Instruction Book page 138

Table of Contents

Advertisement

5 - Operation
1. Engage pump at approximately 300 r.p.m.
2. Turn suction SmartValve towards "Rinsing tank" and pressure
SmartValve towards "Internal Tank Rinsing".
DANGER! Before turning Pressure SmartValve to "Pressure
draining/TurboFiller" it is very important to be sure that the quick
coupler lid is correct and completely mounted to the filling stud
into its locked position. Failure to do so may cause risk of
contamination and injury from quick coupler lid being "shot" off
when pressurized! If not possible to mount lid completely,
lubricate the rubber seal and the grip hooks.
3. When enough water from the rinsing tank is transferred, turn
suction SmartValve towards main tank.
4. Keep/turn pressure SmartValve towards "Spraying position" and
close the agitation valve. Adjust the pressure manually to
approximately 10 bar.
5. Pull out the hose from the reel.
6. Adjust he pressure manually to approximately 10 bar.
7. Wash the sprayer with the cleaning gun.
8. When finished, disengage the pump
9. Retract the hose.
÷
NOTE! Do not let go of the hose. Gently restrict the roll-in of the hose.
If the sprayer is cleaned with a high pressure cleaner, lubrication of the entire machine is recommended afterwards
138
!
!

Advertisement

Table of Contents
loading

Table of Contents