Turbofiller Rinsing - Hardi MERCURY 2000 Instruction Book

Axial-centrifugal
Table of Contents

Advertisement

5 - Operation

TurboFiller rinsing

Rinsing the TurboFiller and chemical containers are done in the
following two ways:
When TurboFiller lid is open
For cleaning empty containers. Put container over the rotating flushing
nozzle in the middle of the TurboFiller so that the nozzle is inside the
container. Press the Chemical Container Cleaning lever and the
TurboFiller suction valve at the same time to activate the flushing nozzle
in the middle of the TurboFiller and empty out the TurboFiller rinsing liquid.
When TurboFiller lid is closed
Use the Chemical Container Cleaning lever to rinse the hopper after filling of chemicals has ended. Press the Chemical
Container Cleaning lever and the TurboFiller suction valve at the same time to activate the flushing nozzle in the middle of
the TurboFiller and empty out the TurboFiller rinsing liquid. Do this 3 times and after the last flushing open the lid to
inspect if the TurboFiller is empty. If not, close the lid again and press the TurboFiller suction valve until the TurboFiller is
empty.
±
ATTENTION! The TurboFiller needs to be cleaned thoroughly after finishing spraying again to be sure it is clean before
spraying other crops that may be sensitive to the chemicals just used. See section Cleaning on page 51 for details.
Adjusting the EVC operating unit
The EVC operating unit must be adjusted with clean water before
spraying with chemical products.
Adjusting the pressure:
1. Select the correct nozzle by turning the nozzle holder if the
equipment contains a double jet. See the 'Spraying techniques'
booklet.
2. The ON/OFF switch (A) is in the down position.
3. The two valves of the spray zones (B) are in the down position.
4. The pressure switch (C) must be activated and set the pressure to
minimum.
5. Put the tractor in neutral and adjust the PTO to the same
revolutions as during spraying.
6. The switch to regulate the pressure must be pressed until the
pressure gauge shows the desired pressure.
To regulate the volumetric valves, proceed as follows:
1. Open both spray zones using the control box.
2. Raise the pressure (e.g. to 10 bar).
3. Close one of the spray zones.
4. With the volumetric valve (D) of the sector closed, adjust the
pressure until the pressure gauge shows 10 bar again.
5. Open the spray zone again and repeat the procedure with the
other spray zone.
6. Test by opening any of the spray zones individually. If the operating unit is correctly adjusted, the pressure should
remain stable.
μ
ATTENTION! WHEN PRESSURE ADJUSTMENT HAS BEEN PERFORMED, IT ONLY SHOULD BE READJUSTED WHEN:
1. ANOTHER NOZZLE WITH A GREATER OR LESSER CAPACITY IS USED.
2. THE NOZZLE OUTLET SIZE HAS INCREASED DUE TO WEAR.
48
D
ON
A
B
B
1
HARDI
ON
C
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Arrow 2000

Table of Contents