Gasket Types
Usually an O-ring is used, but there is also a different type of gasket in
use (F).
How To Remove Lock Ring
If the lock ring needs to be replaced, this can be done by mounting a
connector (A) in reverse direction.
Push the connector over the lock ring.
Place the connector right behind the lock ring and pull to remove the
lock ring from the pipe.

BoomPrime One-Way Valve

If the one-way valves for the BoomPrime system are clogged, they must
be cleaned.
1. Disassemble the two parts.
2. Clean the parts as needed. Check the state of the black O-ring.
3. Assemble the parts again and tighten with a torque of 1 Nm.
μ
ATTENTION! If any part is worn or damaged, it should be replaced.