6. Ethernet Settings

This manual explains communication parameter specifications and cable wiring.
Note
This document and this project file can only operate with the settings and commands
described in this chapter. For communication other than this setting, it is necessary to modify
the project file.
6.1. Ethernet Communications Settings
The settings for establishing Ethernet communication are as follows.
6.1.1. Communication setting between setting PC and Smart Camera
In this document, the setting procedure of the smart camera by the setting PC is explained
using the setting contents in the table below as an example.
Setting item
IP Address
Subnet mask
Gateway
* For the use cases in this document, setting the gateway is unnecessary because the
devices are connected within the same segment of the network.
6.1.2. Communication Setting Between Ethernet Unit and Smart Camera
The connection procedure of the Ethernet unit and the smart camera is explained using the
settings in the table below as an example.
Setting item
IP Address
Subnet mask
Gateway
Port number
* For the use cases in this document, setting the gateway is unnecessary because the
devices are connected within the same segment of the network.
On PC used for settings
192.168.188.100
255.255.0.0
Blank ( default)
NX1P2-9024DT
(Built-in EtherNet/IP Port)
192.168.188.1
255.255.0.0
-
(Set in the software)
Smart camera
192.168.188.2 (default)
255.255.0.0 (default)
0.0.0.0 (default)
Smart camera
192.168.188.2 (default)
255.255.0.0 (default)
0.0.0.0 (default)
49211 (Default)