2022-08-12
When one or two 900 W AC Titanium PSUs are configured and the input voltage ranges from 100 V
AC to 127 V AC, the output power decreases to 550 W.
When one or two 2000 W AC Platinum PSUs are configured and the input voltage ranges from 200
V AC to 220 V AC, the output power decreases to 1800 W.
When one or two 3000 W AC Titanium PSUs are configured:
If the input voltage ranges from 100 V AC to 127 V AC, the output power decreases to 1300 W.
If the input voltage ranges from 200 V AC to 220 V AC, the output power decreases to 2500 W.
If the input voltage ranges from 220 V AC to 230 V AC, the output power decreases to 2900 W.
The server supports six fan modules.
The fan modules are hot-swappable.
N+1 redundancy is supported. That is, the server can work properly when a single fan
fails.
The fan speed can be adjusted.
Fan modules of the same part number (P/N code) must be used in a server.