68 Mechanical installation
Drive module without output cable connection terminals (option
■
+0H371)
The power cables can be connected directly to the drive module input and output
terminals with cable lugs or by busbars.
Drive module without pedestal (option +0H354)
■
The drive module without pedestal can be mounted on a wall or in an enclosure with
four screws through the mounting holes at the top and bottom of the module.
Make sure that the enclosure mounting plate and frame are strong enough to carry
the weight of the drive module.
Attaching the drive module to a mounting plate or wall
■
Use the support bracket 3AUA0000096082 (included in the assembly kit
3AXD50000453900) if you attach the drive module directly to a mounting plate or
wall. The support bracket prevents the drive module screws from chafing against the
plate.
M4×12 Torx
Alternatives for grounding the drive module
■
You can ground the drive module from its top back to the cabinet frame with these
alternatives:
1.
from the grounding hole
2.
to a Rittal punched section with the fastening bracket.