INSTALLATION
Installation of the shifting cable
For internal 11-speed
Shift lever side
1
2
3
(A)
4
(A)
To be continued on next page
(A)
(B)
(B)
Set the shift lever to 11.
Loosen and remove the inner hole cap.
Insert the inner cable into the hole in the
winder unit, and then pass it through
the hole in the cable adjustment barrel.
Pull the inner cable so that the inner
cable drum fits into the hole in the
winder unit.
25
NOTICE
•
Use a shifting cable with one inner cable
drum.
Cable with one inner cable drum: OT-SP41
•
Make sure that the shield cap is at the shift
lever end.
(A)
Wire end hooking cap
(A)
Hole in cable adjustment barrel
(B)
Hole in winder unit
(A)
Inner cable drum
(B)
Hole in winder unit