MTS3610 Installation Guide
Note: The side of the chassis with the power supply units will sit flush with the vertical supports of the rack.
The side of the chassis with the QSFP connectors will sit at the edge of the shelf closer to the center of the
rack.
Note: place the chassis as low as possible in the rack to keep the center of gravity as low as possible.
Step 2.
Insert four caged nuts into the rack on the side you plan to have the connectors. Note
the U number on the rack.
Step 3.
Screw the rail slides onto the rack.
Step 4.
Insert four caged nuts into the rack on the side you plan to have the powers supplies,
and spines. Use the same U number on this side of the rack as you used on the rail
side of the rack.
Step 5.
Prepare the four bolts and keep them within reach.
Step 6.
Slide the shelf onto the rail slides.
Step 7.
Connect the shelf to the rack.
Rev 1.2.2
Figure 3: Vertical Rails to Cabinet Measurement
Figure 4: Caged Nut Insertion
Figure 5: Rail Slide Installation
The caged nuts
are separated by a
single space.
Mellanox Technologies
4