Culligan ClearLink PRO Installation, Operation, And Service Instructions With Parts Lists page 13

Wireless filtration control
Hide thumbs Also See for ClearLink PRO:
Table of Contents

Advertisement

4.
Connect the inlet on the RO/Filter
system to the port marked "RO/
Filter ►." Wet the end of the plastic
tubing with water and push it into
the quick connect fitting adapter
approximately 5/8" until it stops.
NOTE
The control box must be in a vertical position.
NOTE
If space does not allow for mounting the control box onto the valve, it can be mounted on a wall
and connected using flexible lines. (purchased separately).
NOTE
Flare fittings used on cut-to-fit PEX line prevent the connecting nut from being threaded on more then
1-2 turns. Therefore, it is recommended that the MS031611 adapter listed in the "Installation Fittings and
Replacement Parts List" section be used. The flare fitting of the PEX line should be cut off and the tubing
inserted directly into the push-to-connect end of the MS031611 adapter.
NOTE
All filters and RO membranes should be flushed before connecting any ClearLink device to the
filtration/RO system.
NOTE
The port marked "RO/Filter" is plugged for remote system installations (Water supply is not the
same as the sink such as basement installations). This port is normally plugged when installing
the filtration/RO system in a location other than the kitchen cabinet.
NOTE
Use the supplied adapter if your system uses a 1/4" tube.
Cat. No. 01033136
3.
Connect the control box to the cold water shut-off valve
and the water line to the Faucet as shown. Culligan
recommends 1/2 - 3/4 additional turns past finger-tight.
CAUTION!
The stationary hex nut on the outlet
of the ClearLink should not be used
to over-tighten the hose fitting.
Inlet from ClearLink
bottom side port
Installation
13