Check The Aftertreatment Exhaust Piping; Check The Air Conditioning Operation - SANY SY215C LC Operation And Maintenance Manual

Table of Contents

Advertisement

SY215C LC/SY225C LC Excavator OMM

Check the Aftertreatment Exhaust Piping

WARNING!
Never operate a machine with a damaged or defective exhaust system, exhaust leaks, or
restrictions. Failure to follow this warning could result in death or serious injury.
CAUTION!
Make sure that the engine is off and that the exhaust components have cooled so they can be
touched without burning. Failure to do so could result in injury.
1. Prepare the machine for service. See "Maintenance
Safety" on page 2-8.
2. Open the engine cover.
3. Locate the exhaust system (2) under the engine cover,
next to the engine.
4. Inspect the exhaust system and its mount for leaks or
signs of damage.
5. Check the connection to the expansion pipe (1) for leaks
or signs of damage.
6. Make sure the exhaust pipe is clear and not restricted.

Check the Air Conditioning Operation

CAUTION!
The air conditioning system is under pressure Working on it could create a hazardous
situation, which could result in injury. Contact a SANY dealer for repairs.
With the engine running:
Press the OFF button (1) and make sure no heat is
present.
Press the fan switch (2) to check start-up, airflow,
and adjust the fan speed.
Press the temperature control button (3) to adjust
the heat temperature and check if the air temperature changes from warm to hot.
Press the A/C button (4) and check if the air temperature changes from warm to cool.
Check the recirculated/fresh air control switch (5) function.
SANY
Operation and Maintenance Manual — 1219
1
Fig. 5-6
1
2
OFF
5
Fig. 5-7
Maintenance
2
3
MODE
AUTO
TEMP
A/C
4
5-23