Diagnostic Tests
The following tables list test results that are displayed after
running each diagnostic test.
Table 9 - Diagnostic 1 Test Results
Test Result
Expected Value
Radio Status Awake or Sleep
RSSI Value
Above -80
Battery Level 4-6
Packet
90 - 100%
Effi ciency
Table 10 - Diagnostic 2 Test Results
Test Result
Expected
Value
Radio Status Awake or Sleep
Last Wake
hr : min : sec
Next Wake
hr : min : sec
Last SYNC
hr : min : sec
90
Integrated Sensor System
Details
Shows current radio status
Low: -92 to -85, Medium: -85
to -80, High: Above -80
LOW, MED, HIGH
Compares data packets
received with data packets
transmitted
Details
Shows current radio status
Elapsed time since last wake
Time until next wake
Elapsed time since last sync
with Soil Manager
Table 11 - Diagnostic 3 Test Results
Test Result
Expected Value
Vbat
4-6
Xbee
8.04 B Awake
SDHC
Card Ready
CH 1
Sensor [x] 2mA
CH 2
Sensor [x] 2mA
Rain Bird Support
Rain Bird Technical Services
866-GSP-XPRT (477-9778)
+1-520-741-6100 (Non-toll-free outside U.S. and Canada)
Visit us at www.rainbird.com/ISS
Details
OK/FAIL (Battery voltage
indication)
OK/FAIL (FAIL indicates
possible radio module
failure)
OK/FAIL (SD card not
installed or failed)
Only used for engineering
testing