Intermec EasyCoder 3240 Developer's Manual page 87

Intermec printer language (ipl)
Hide thumbs Also See for EasyCoder 3240:
Table of Contents

Advertisement

Error Codes and Possible Solutions (continued)
Error
Code Description of Problem
52
Invalid UDC/UDF bitmap cell height/width or
intercharacter space.
53
Not enough room in RAM to store UDC or UDF. Remove or reduce formats, fonts, or UDCs.
54
Invalid UDC command syntax.
55
Not enough room in RAM to store downloaded
font.
56
Flash file system error.
57
Invalid parameter.
60
No RFID support.
61
No RFID tag found.
62
Access outside of the RFID tag memory.
63
RFID number conversion error.
64
RFID inactive (off ).
65
RFID tag type does not support the selected
option.
66
RFID module overheated.
67
RFID module duty cycle exceeded.
68
RFID lock error.
69
RFID Access error.
Intermec Printer Language (IPL) Developer's Guide
Solution
Verify that the UDC/UDF bitmap cell height/width or
intercharacter space is within the specified values for n. For
more information, see these commands in the IPL
Command Reference Manual:
• "Bitmap Cell Height for Graphic or UDF, Define"
• "User-Defined Character Field, Create or Edit"
• "Intercharacter Space for UDF, Define"
Correct the UDC command syntax.
Add more printer RAM.
Correct the syntax.
The printer is unable to access the RFID module. Contact
your local Intermec representative.
The RFID module has determined that the printer does not
have RFID media loaded. Load RFID media. Verify that
the TAGADJUST value aligns the tag over the antenna. For
help, see the "RFID Parameters, Set" command in the IPL
Command Reference Manual.
The defined RFID tag field specifies a position outside of
the tag's memory or the tag read/write operation was not
successful (bad tag). Verify that the field specifies a position
within the tag's memory. For help, see the RFID Tag Field
Setup command in the IPL Command Reference Manual.
You have entered an invalid hex or numerical (NUM)
format in the data string. Enter a valid value.
You have a printer with an RFID module and you have
defined RFID commands, but you have turned RFID mode
off. Turn RFID mode on. For help, see the RFID
Parameters, Set command in the IPL Command Reference
Manual.
An application has sent a command with an argument that
is not supported by the printer's tag type. Verify that the
application commands match the printer's tag type.
The printer RFID module has exceeded its recommended
operating temperature and shut down automatically. Wait
until the module has cooled to the recommended operating
temperature before you try to print tags again.
The printer RFID module has exceeded its recommended
duty cycle and shut down automatically. You may need to
check the RFID module settings. For help, see the Basic
Reader Interface (BRI) Programmer's Reference Manual (P/N
937-000-xxx).
You are trying to write data to a locked RFID tag. Use the
"RFID Tag Protect" command to unlock the tag and try
again.
Check the syntax for the "RFID Tag Write Field, Create or
Edit" command.
Chapter 5 — Troubleshooting