Chapter 5 — Troubleshooting

Interpreting Error Codes and Solving Problems

Error Codes and Possible Solutions
Error
Code Description of Problem
00
No error.
02
Invalid number of bar code characters
(UPC/EAN).
11
Invalid bar code data.
12
Data count exceeded.
21
Quantity or batch count out of range.
22
Field increment/decrement out of range.
25
Invalid format transmission syntax.
26
Invalid page transmission syntax.
27
Invalid font transmission syntax.
28
Invalid UDC transmission syntax.
33
Invalid field delimiters.
34
Invalid escape command.
35
Invalid data shift command.
36
Invalid or undefined format number.
37
Insufficient room in RAM to print format.
38
Invalid or undefined field number.
41
Syntax error for program commands.
42
Insufficient room in RAM to store format.
43
Too many fields in label format.
46
Undefined statement.
72
Most of the problems you may encounter cause the printer to send an error
code to the host. To correct the error, find the error code in the following
table and complete the instructions in the solution column.
Note: For information on specific commands, see the IPL Command
Reference Manual.
Solution
No action is necessary.
Verify the number of bar code characters used. For more
information, see the "Bar Code, Select Type" command in
the IPL Command Reference Manual.
Verify data in the label format.
Data count should not exceed what is specified for the field.
Quantity of labels or number of batches should be between
1 and 9999.
Quantity should be between 1 and 9999.
Check the "Format, Transmit" command syntax.
Check the "Page, Transmit" command syntax.
Check the "Font, Transmit" command syntax.
Check the "User-Defined Characters, Transmit" command
syntax.
Check for all pairs of field delimiters and make sure both are
numeric, or both are alphanumeric.
Correct the escape command syntax.
Correct the shift command syntax.
Verify that the format numbers are between 0 and 19.
Reduce the number of data fields in the format or add more
DRAM.
Verify the field number in the label format.
Check the program command for proper syntax.
Empty the buffer contents. If the format still does not fit,
delete some fields or other data from the format. You may
have to remove or reduce the UDCs, formats, or fonts if
necessary.
To determine the amount of installed and available memory,
send the "Memory Usage, Transmit" command.
You can use up to 200 fields in a format and each field can
use up to 250 characters. Reduce field size or delete some
fields.
Check the statement syntax.
Intermec Printer Language (IPL) Developer's Guide