Select recovery mode for the event of a power failure.
OFF: Unit goes into idle at power recovery.
ON: Unit automatically reverts to status just before power loss and begin operation once again from
that point.
Default setting is "OFF"
1. Enter user setting
Fwd
Rev
Press 2 sec
2. Change the Auto-resume setting
Fwd
Rev
①
Fwd
Rev
③
3. Exit user setting
Fwd
Rev
AutoR
Sync
②
①
AutoR
Sync
②
①
AutoR
Sync
④
③
AutoR
Sync
Press 2 sec
4. OPERATION PROCEDURES
① Press the Power key.
② Press the Encoder dial for two seconds while current
rpm is on the screen.
Unit enters user setting.
① Turn the Encoder dial and select "Pon".
RPM display: "Pon" flashes
② Press the Encoder dial.
RPM display: Current setting flashes
③ Turn the Encoder dial to select ON/OFF.
④ Press the Encoder dial to finalize.
After completing the setting, press the Encoder dial for
two seconds. Display reverts to previous screen and
shows current rpm.
28
Auto-resume Function