Chapter 3 Controller Descriptions and Operation
SEt value and actual temperature.
4) The equipment may be initiated immediately when
remaining AS time.

3.7 Timer for automatic terminating (optional)

1) The function of timer is optional.
2) Press
for more than 2 seconds to display Ht, scroll the menu by
displayed, then press
confirm and exit the SEt screen or exit automatically in 4 seconds.
5) When the equipment is in running mode, press
to initiate timing. The timer starts to count down. When the time of ASd elapses, the
circulation pump and heating will stop automatically to terminate constant temperature
control.
6) The equipment may be terminated immediately when
remaining ASd time.

3.8 Temperature Programming (optional)

1) The function of temperature programming is optional.
2) Press
and
displayed. Press
setting by pressing
original temperature, press
enter the setting of second segment.
3) Following the steps as for the first segment for segments 2, 3 ... to 6 maximum. If segments of
less than 6 are desired, for example only 2 segments are necessary, use 00:00 for t3 after
confirmation of M2.
4) Press
to display n, which means the number of program circles.1~99 means 1 cycle to 99
circles maximum and 0 means unlimited circles. Press
5) Press
and
be terminated immediately when
segments.
6) When the programming is in progress, press
temperature, remaining time and cycles of active program. The parameters are cycled and
displayed for 2 times with each delay of about 2 seconds, and then exit automatically.
XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/ 
to enter. Press
at the same time and then release. The parameter of first segment t1 is
to display original time, press
to display temperature of the first segment M1; Press
at the same time to initiate or terminate programming. The program may
to get the desired value, press
+
at the same time and then release
for a new value, confirm the setting by pressing
to confirm and exist.
is operated regardless of the remaining program
shortly to display the segment number,
/
31
DSGO0708-2-V211119/UXP8011-CD6400/CLASS I/NFL/RT+5~+100°C