Error messages / continuation
Figure 37: Error message7
Figure 38: Error message8
Figure 39: Error message9
Further (non-control-relevant) operating faults are described in chapter 14.
BA_PH_436-100_EN_44-21.docx
a) The voltage monitoring at the load input of the
controller for the thicknessing table has tripped.
Cause:
b) Fuse F3 has tripped.
c) Power unit G1 defective or overloaded.
Check the 24 V voltage, the fuse F3 and/or
Remedy:
the power supply for the thicknessing table.
The axis constantly consumes too much current.
Positioning was aborted because the maximum
axis current was exceeded.
Cause:
a) The thickness table was moved against block
b) Spindle guide is too sluggish
c) Thickness table extension runs sluggishly
a) Release blockade
b) Clean and grease spindle guide
Remedy:
c) Check the table extension mechanically
Abrupt increase in current. The positioning was
Cause:
stopped because the dl/t monitoring has triggered.
The thickness table was moved against block.
If necessary, free the workpiece from the machine and
loosen the blockage. Check the calibration values and re-
Remedy:
calibrate if necessary. Check the limit switches at the top
and bottom.