10.2 Activating the Controller
The controller activates automatically when the machine is switched on. The main menu appears.
➔ Switch ON the machine
Figure 16: Screen at start-up (booting)
• When booting, the main menu initially appears in German language, graphically unclear, blurred and with a
( Figure 16) → As soon as the main menu appears clear and sharp, the position controller and the
i
red
machine are ready for operation (see Figure 17).
• Press the "Machine" button for normal positioning mode (see 10.3).
• To calibrate the table height, press the button "Setup" (procedure see 10.5).
Symbol
If the "Info" icon still appears in red after booting, then tap on the icon to open the "Info"
menu and explore the cause of the problem. For more details refer to
10.3 Operating States & Language ("Info" Menu)
By tapping the symbol
resp.
version number, the year of manufacture and various messages are displayed here. In addition, the menu lan-
guage (German, English or French) for the control system can be set here.
Figure 18: Info menu with status messages
• Status messages (example Figure 18): Here the required 24 V voltage for the thicknessing table is missing.
In addition, there is a motor fault WSK (winding protective contact). Operation is only possible after the
faults have been remedied. If the end position symbol is active, you must first move out of the end position
range so that the message becomes inactive. Afterwards, positioning can be resumed ( 10.4.1).
• Detailed information about all error and warning messages can be found in the section 10.7.
• Tapping the flag symbol at the bottom left opens the language menu (see Figure 19).
The desired menu language can be chosen here.
BA_PH_436-100_EN_44-21.docx
Figure 17: Screen "ready for use"
you can access the "Info" menu. Various operating states, the machine and
Figure 19: Language menu
10.3 and
10.7 .
30