MA32/D
Chapter 4. SOFTWARE
4.3. USER INTERFACES
DEVICE
NR
DESCRIPTION
Set system time and time zone. If the device is connected to the internet, it will try to synchronize its RTC (real
time clock) to an NTP time-server.
Shows measured mains voltage if the device does support it. If not, the user has to configure the current mains
voltage which is required for the PSU limiting.
If the device has more than one PSU, it will indicate which one is plugged in. (HP² only)
Shows PSU Load.
Shows PSU reduction, which will reduce the output level of all channels simultaneously to not overload the PSU.
FAN MODE "NORMAL" is the recommended mode to keep all components as cool as possible to improve
lifetime. When not much output power is required, the FAN MODE could be changed to "SILENT " or "PASSIVE"
(LP² only) which will use different fan speeds to reduce noise.
Shows actual housing fan speed (depends on internal temperature).
En-/disable mute on startup, if enabled, the "MASTER MUTE" will be set on every start up.
En-/disable volume ramp after the master mute is disabled. This will linearly increase the dB value until it is
reached its desired value.
Master Volume ramp-up-time in seconds, if enabled.
Enable remote mute, this will provide a GPI interface to mute the entire device, also known as dead man switch.
Which require an external Innosonix Remote Mute Server, multiple devices can share one server.