Step 2: Choosing A Location For The Unit - Xantrex Freedom X 2000 Owner's Manual

230v inverter
Table of Contents

Advertisement

Step 2: Choosing a Location for the
Unit
FIRE AND EXPLOSION HAZARDS
Do not install the Freedom X in compartments containing
l
batteries or flammable materials, or in locations that require
ignition-protected equipment. This includes any space
containing gasoline-powered machinery, fuel tanks, or joints,
fittings, or other connections between components of the fuel
system. This equipment contains components that tend to
produce arcs or sparks.
Do not install on or over combustible surfaces.
l
Do not cover or obstruct the ventilation openings.
l
Do not install the Freedom X in a zero-clearance
l
compartment. Overheating may result.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
The Freedom X should only be installed in locations that meet the
following requirements:
Dry. Do not allow water or other fluids to drip or splash on
n
the Freedom X. Do not mount the Freedom X in an area
subject to splashing water or bilge water.
975-0822-01-01
WARNING
Cool. Normal air temperature should be between -20 °C and
n
40 °C—the cooler the better, for increased efficiency and
product life extension.
Ventilated. Allow at least 12 cm of clearance at the wiring
n
access (AC and DC) end of the Freedom X allowing air
intake flow through the fans. Provide similar clearance at the
opposite end where the air vent is located. The more
clearance for ventilation around the unit, the better the
performance. Do not allow the ventilation openings to
become obstructed.
Safe. Do not install the Freedom X in the same
n
compartment as batteries or in any compartment capable of
storing flammable liquids like gasoline.
Close to the battery compartment and the AC mains
n
and load panels. Avoid excessive cable lengths (which
reduce input and output power due to wire resistance). Use
the recommended cable lengths and sizes, especially
between the battery banks and the Freedom X.
Protected from battery acid and gases. Never allow
n
battery acid to drip on the Freedom X or its wiring when
reading specific gravity or filling the battery. Also do not
mount the unit where it will be exposed to gases produced
by the batteries. These gases are very corrosive, and
prolonged exposure will damage the Freedom X.
Basic Installation Procedures
19