Figure 14 Config>Turret Screen After User Alters Rotation, Seek Speed, And Index Speed - ferrotec Genius II Quick Start Manual

Table of Contents

Advertisement

1.5.3 Configuring the Turret Control Module
Figure 14 Config>Turret Screen After User Alters Rotation, Seek Speed, and Index Speed
0101-9031-0, Rev. B
Step
Action
1
First select the desired rotation direction and mode (i.e., either
unidirectional or bidirectional). If the default (CCW) is appropriate,
skip this step and proceed to Step 2. To change the rotation direction,
touch the Rotation button to toggle to CW.
Next select the number of pockets. To do so, touch the Pockets
2
button repeatedly until the button displays the correct number.
3
Set the index motor's seek speed. If the default jog speed value (5 %)
is acceptable, skip this step and proceed to Step 4. To change the
value:
a) Touch the Seek Speed button to display a keypad popup and use
it to enter the desired value.
b) Touch the keypad's Enter button to close it and set the new jog
speed value. The value you entered will then appear on the Seek
Speed button. NOTE: The drive motor's rotation speed is four
times that of the turret.
4
Select the drive motor's index speed. To do so:
a) Touch the Index Speed button to display a keypad popup and
use it to enter the desired value.
b) Touch the keypad's Enter button to close it and set the new jog
speed value. The value you entered will then appear on the Index
Speed button.
In Figure 14, the user has changed the Rotation to clockwise, the
Seek Speed to 3 %, and the Index Speed to 85%.
Touch the Activate Motor button. The Config>Turret screen will now
5
appear as shown in Figure 15, with 1 displayed on the Pocket button.
13
1.5 Configuring the Control Modules
Genius II Quick Start Guide