Profound Vibration Monitoring
Profound VIBRA geophone
The Profound geophone for the VIBRA range
has been designed for high-performance
vibration monitoring.
Advanced mounting
The ball joint in combination with the wall
bracket facilitates precise orientation of the
geophone in the correct x-, y- or z-direction,
as well as enabling fine tuning of the vial.
Digital ID
The geophone has an electronic datasheet,
which also includes the serial number.
Therefore, the source of measurement data
can always be traced.
High-performance
Besides continuously monitoring the x-, y-
and z-direction, the VIBRA also automatically
corrects the measurement data for the
individual sensitivity of each geophone
channel.
This
guarantees
measurements and performance.
Plus
The VIBRA geophone in combination with the
+
VIBRA
offers the following extras:
Digital measurement of the geophone's
-
inclination, assuring that measurements
are
carried
out
positioned geophone.
-
Based on data from the electronic
datasheet, the VIBRA
the sensitivity, but also the resonance
frequency and the quality factor with the
help of digital correction filters.
More information about the Profound VIBRA
range can be found in the technical
specifications of the VIBRA.
P.O. Box 469
2740 AL Waddinxveen
The Netherlands
VIB030/01/2006
Profound reserves the right to revise this documentation or to make improvements
high-quality
with
a
correctly
+
not only corrects
Tel. + 31 182 - 640 964
info@profound.nl
www.profound.nl
or changes in the product(s) at any time.
VIBRA geophone
Technical specifications VIBRA geophone
Channels
Sensitivity
Resonance frequency (f
res
Output Resistance (R
)
out
Quality factor (Q)
Distortion at 18 mm/s and 12 Hz
f
within tolerance
res
Sensitivity of the vial
Electronic datasheet (ID)
Temperature range (operating)
Protection rating
Size
Mass
Moving mass
+
Extra on VIBRA
Accessories
2
10
1
10
Geophone f = 8 Hz Q=0.707
DIN 45669-1 calibration point
DIN 45669-2 free standing geophone a < 3m/s
Geophone displacement limit 0.8 mm
Geophone displacement limit 0.8 mm inclination 5 degrees
Vibra v
= 100 mm/s u
max
0
10
0
10
3 (x-, y-, z-direction)
23.3 Vs/m
)
8 Hz ± 0.5 Hz
330 Ohm
0.75
< 0.2 %
< 15º
53 arc minutes (R130 mm)
Serial number; calibration
date; sensitivity; f
res
- 20°C to + 60°C
IP65 according to
DIN 40 050/IEC 529
Ø 74 mm
0.48 kg
11 ± 0.5 g (each channel)
Inclination measurement
cable reel of 50 m
MEASURING RANGE VIBRA
2
and f < 100 Hz
< 0.8 mm
max
1
10
10
frequency [Hz]
; R
; Q
out
2

Advertisement