The under Peak Type selected setting is also used for the VIBRA
function, described in paragraph 5.3.6.
In the PC software you can look up the applied category in the data under tab Saved traces. The chosen
category line in the Velocity/Frequency graph is also thicker than the other category lines.
The building category set for FFT/Method I cannot be changed in the VIBRA PC software. According to
FFT/Method I the system saves related to the chosen category the most relevant peak values per interval.
With Zero Crossing/Method II you are able to change the category in the PC software. Select the
Velocity/Frequency graph and choose Zero Crossing/Method II under Frequency of the Plot Settings.
Then you can select the desired category under Date/Time.
+
-option)
5.3.4
Code (VIBRA
The VIBRA processes the data in accordance with DIN 4150-3 June 2001.
The VIBRA-sbr does the same in accordance with the Dutch code SBR part A, B – 2002.
VIBRA
+
- users have the option to process the data in accordance to either DIN 4150-3 (and
simultaneously to DIN 4150-2) or to the Dutch code SBR Part A, and simultaneously to part B - 2002.
The default VIBRA
+
setting is DIN. To edit and change to SBR, enter the Code option and select with
the -key SBR. Press OK.
Manual Profound VIBRA-series, version 2.00
30