H P 16530/31 A - Performance Tests
3-6. Bandwidth (-3dB) Test
SPECIFICATION:
De to 100 MHz
EQUIPMENT:
Signal generator ........................................................................ HP 86566
Cable type N(m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP 115006
Adapter type N(m)-to-6NC(m) .................................................... HP 1250-0082
DESCRIPTION:
This test verifies that the signal amplitude will not decrease more than 3 dB through the
specified operating frequencies.
PROCEDURE:
a.
Turn instrument power off.
b.
Connect signal generator to acquisition card as shown in figure 3-1, and set the output
for a 200kHz sine wave with an amplitude of 300 mV.