Installation Requirements - Barco DP2K C User And Installation Manual

Table of Contents

Advertisement

General

2.1 Installation requirements

Environmental conditions
The table below summarizes the physical environment in which the DP2K-xxC may be safely operated or
stored.
Environment
Ambient Temperature
Air cleanliness
Humidity
Altitude
Let the projector acclimatize after unpacking. Neglecting this may result in a startup failure of the
Light Processor Unit.
Cooling requirements
The projector is fan cooled and must be installed with sufficient space mainly in the front of the projector head,
minimum 20 cm (8 inch) to ensure sufficient air flow. It should be used in an area where the ambient
temperature, as measured at the projector head air inlet and at the power unit air inlet, does not exceed +35°C
(+95°F).
In case the projector is built inside a Hushbox (e.g. Escape configuration) then the ambient temperature may
not exceed the specified temperature of the Hushbox. See documentation of the used Hushbox for specific
cooling requirements.
The installation of an exhaust system is MANDATORY. The installed exhaust blower must remove an air
volume of minimum 6,65 m
Air flow in/out
The projector must be installed with sufficient space around the projector head, minimum 20 cm (8 inch) to
ensure sufficient air flow.
1.
For PRC (People's Republic of China) the certified altitude is specified on the product label.
22
R5905752 /16
DP2K C
Operating
10°C (50°F) to 35 °C (95 °F)
Clean office environment (equivalent with
cleanroom standard ISO 14644-1 ISO Class
9)
5% to 85% RH Non-condensed
-60 (-197Ft) to 3000m (9843Ft)
3
/min (235 CFM).
Non-Operating
-15°C (5°F) to 60°C (140°F)
n.a.
5% to 95% RH Non-Condensed
1
-60 (-197Ft) to 10000m (32810Ft)