CAUTION: Xenon compact arc lamps are highly pressurized. When ignited, the normal operating
temperature of the bulb increases the pressure to a level at which the bulb may explode if not
handled in strict accordance to the manufacturer's instructions. The bulb is stable at room
temperature, but may still explode if dropped or otherwise mishandled. Whenever the lamp house,
containing a xenon lamp, has to be dismantled or whenever the protective container or cloth has to
be removed from the xenon lamp, authorized protective clothing MUST be worn!
WARNING: Always wear face protection (full face shield) when handling xenon lamps.
WARNING: Always wear protective clothing (welder's jacket) when handling xenon lamps.
WARNING: Always wear clean leather gloves with wrist protectors when handling xenon lamps.
Required tools
Flat blade screw driver.
5 mm Allen wrench.
17 mm open-end wrench (2 pieces).
Lamp protective container or protective cloth with two binders.
How to remove the xenon lamp from the lamp house?
1.
Release the xenon lamp from its socket by removing the hexagon socket head cap screw and washer as
illustrated. Use a 5 mm Allen wrench.
Image 4–6
2.
Remove the Lamp House side cover by releasing the two retaining thumbscrews as illustrated.
Lamp & Lamp House
R5905752 /16
DP2K C
43