3 NETWORK CONFIGURATION

Perform the following steps to configure the DSXpert unit for network communication:
Step 1. Connect the DSXpert chassis to a terminal or PC. Connect the COMM IN port on
the rear of the DSXpert chassis to a terminal or PC as shown in COMM Port section,
20. Refer to
Press the ENTER key on the keyboard several times. The terminal should display the
following:
n:OK
Where n is the chassis number from 1 to 8 assigned via DIP switch settings.
Note: If the terminal screen does not display any characters being typed, the ECHO
setting is probably turned off. To turn echo on, type the following (characters will not be
shown), and press return:
Where n is the chassis number. For example, SET UNIT 1 ECHO ON. The characters
being typed should now display.
Step 2. Set Factory Defaults. Initialize the DSXpert unit by restoring its factory defaults.
Enter the following command:
SET UNIT n FACTORY DEFAULTS
Where n is the chassis number.
Step 3. Enter IP addresses of the chassis, default router, and subnet mask. Enter the
following commands to set the IP addresses of the DSXpert unit, default router and subnet
mask:
SET UNIT n IP ADDRESS x.x.x.x
SET UNIT n DEFAULT ROUTER x.x.x.x
SET UNIT n SUBNET MASK x.x.x.x
Where n is the chassis number and x.x.x.x is the IP address.
Step 4. Enter passwords. Enter the following commands to set passwords for accessing the
DSXpert unit. TELNET password allows full access to DSXpert unit commands via telnet
sessions. TFTP password allows flashing of DSXpert unit firmware. MENU password allows
access to menu screen only. All passwords are initially set to NONE (no password). Each
password entered must be unique.
SET UNIT n TELNET PASSWORD oldpassword|NONE newpassword|NONE
SET UNIT n TFTP PASSWORD oldpassword|NONE newpassword|NONE
SET UNIT n MENU PASSWORD oldpassword|NONE newpassword|NONE
Tables 7
and
8
for proper cable and pin connections.
SET UNIT n ECHO ON