Power Connection - ADC DSXpert 2005 Installation Instructions Manual

Remote test access system modular chassis and corresponding chassis components
Table of Contents

Advertisement

ADCP-80-552 • Issue 2 • November 2000

2.3 Power Connection

Connect the -48V dc power supply as shown in
shielded. For power supply redundancy, attach each pair of connectors to a separate power
source. If only one power source is available, to create power supply redundancy, join the two
sets of connectors in parallel to each other.
Warning: To fully power down the unit equipped with -48V dc connectors, shut off power at
the connecting power source. Do not disconnect dc connectors at terminal blocks on rear of
chassis while power is being supplied to the unit.
Page 28
 2000, ADC Telecommunications, Inc.
Figure 22. Connection of Power Supplies (–48V)
Figure
22. Use wire gauge 18-22 awg,
14049-A