ADC DSXpert 2005 Installation Instructions Manual page 15

Remote test access system modular chassis and corresponding chassis components
Table of Contents

Advertisement

DS6 PACKAGE
1
2
3
4
Function
Off
Not used (default).
Off
Not used (default).
Off
Factory use only (default).
Off
Not used (default).
5
6
7
8
Function
Off
Off
Off
On
Sets unit ID to 1 (default).
Off
Off
On
Off
Sets unit ID to 2.
Off
Off
On
On
Sets unit ID to 3.
Off
On
Off
Off
Sets unit ID to 4.
Off
On
Off
On
Sets unit ID to 5.
Off
On
On
Off
Sets unit ID to 6.
Off
On
On
On
Sets unit ID to 7.
On
Off
Off
Off
Sets unit ID to 8.
DS5 PACKAGE
1
2
3
4
Function
On
Enables TL1 error responses.
Off
Enables ASCII error responses (default).
On
Echo on COMM port Enabled.
Off
Echo on COMM port Disabled (default).
On
On COMM Baud Rate = 2400
Off
On COMM Baud Rate = 4800
On
Off COMM Baud Rate = 9600 (default)
Off
Off COMM Baud Rate = 19200
5
6
7
8
Function
On
Modem Timeout Enabled.
Off
Modem Timeout Disabled (default).
On
AUX Port circuit is present (default).
On
On AUX Baud Rate = 2400
Off
On AUX Baud Rate = 4800
On
Off AUX Baud Rate = 9600 (default)
Off
Off AUX Baud Rate = 19200
Table 3. DIP Switch Positions, DS6 Package
Notes
Set to Off.
Set to Off.
Set to Off.
Set to Off.
Notes
Set switches to assign an ID number to the unit, for
identification when daisychained with other other
units. Stand- alone chassis and first chassis in daisy-
chain should be set to an ID of 1. The first chassis is
defined as that connected to the external operating
support system. Subsequent chassis in daisy-chain
should be set in sequential ID order. Up to 4 chassis
can be daisy-chained.
Table 4. DIP Switch Positions, DS5 Package
ADCP-80-552 • Issue 2 • November 2000
Notes
Set to On if using TL1. For all other
applications, set to Off.
Set according to preference. However,
for WinTAC applications, set to Off.
All DSXpert units and control
devices MUST be set to the same COMM
port baud rate.
Notes
When enabled, disconnects users
communicating
to DSXpert chassis via modem after user-
defined time of inactivity.
Set to On.
Set AUX port baud rate for WinTAC and
Telnet applications. To baud rate must be
equal to or less than the baud rate for
COMM IN. For all other applications, set
to Off.
© 2000, ADC Telecommunications, Inc.
Page 15