Download Print this page

ADC DS3 Installation Instructions Manual

Hide thumbs Also See for DS3:

Advertisement

Quick Links

Content
INTRODUCTION ........................................................................... 1
Revision History...................................................................... 1
Trademark Information ................................................................. 1
Admonishments ...................................................................... 1
General Safety Precautions .............................................................. 2
1
DS3 ADAPTER KIT INSTALLATION PROCEDURE ................................................. 2
2
CUSTOMER INFORMATION AND ASSISTANCE .................................................. 6

INTRODUCTION

These installation instructions provide the procedures for installing the DS3 Adapter Kit in the
Fiber Loop Converter Four-Position Universal Wall Mount Cabinet. The DS3 Adapter Kit is
required whenever a DS3 Fiber Loop Converter is installed in the Four-Position Universal
Wall Mount Cabinet.

Revision History

ISSUE
DATE
Issue 1
06/92
Issue 2
05/99

Trademark Information

ADC and ADC Telecommunications are registered trademarks of ADC Telecommunications, Inc.

Admonishments

Important safety admonishments are used throughout this manual to warn of possible hazards
to persons or equipment. An admonishment identifies a possible hazard and then explains
what may happen if the hazard is not avoided. The admonishments - in the form of Dangers,
Warnings, and Cautions - must be followed at all times. These warnings are flagged by use
of the triangular alert icon (seen below), and are listed in descending order of severity of
injury or damage and likelihood of occurrence.
Danger: Danger is used to indicate the presence of a hazard that will cause severe personal
injury, death, or substantial property damage if the hazard is not avoided.
1059141 Rev A
Wall Mount Cabinet DS3 Adapter Kit
REASON FOR CHANGE
Original
Update to current format style.
ADCP-61-141 • Issue 2 • May 1999
FLC Four Position Universal
Installation Instructions
© 1999, ADC Telecommunications, Inc.
Page
Page 1

Advertisement

loading

Summary of Contents for ADC DS3

  • Page 1: Table Of Contents

    CUSTOMER INFORMATION AND ASSISTANCE ..........6 INTRODUCTION These installation instructions provide the procedures for installing the DS3 Adapter Kit in the Fiber Loop Converter Four-Position Universal Wall Mount Cabinet. The DS3 Adapter Kit is required whenever a DS3 Fiber Loop Converter is installed in the Four-Position Universal Wall Mount Cabinet.
  • Page 2: General Safety Precautions

    Caution: Observe precautions for handling electrostatic sensitive devices such as printed circuit boards. 1 DS3 ADAPTER KIT INSTALLATION PROCEDURE Use the following procedure to install the DS3 Adapter Kit: a) Open the cabinet front cover and the right side panel to provide access to the inside of the cabinet.
  • Page 3 FOR HEALTH AND SAFETY ACT OF 1968. FRONT SIDE 1077-B Figure 1. FLC Universal Wall Mount Cabinet 1-RCV 1-XMT 2-RCV 2-XMT COAXIAL PRINTED CIRCUIT CABLES BOARDS CONNECTOR MOUNTING PLATE 1078-A Figure 2. DS3 Adapter Kit Page 3 © 1999, ADC Telecommunications, Inc.
  • Page 4 CONNECTORS CONNECTORS FOR CIRCUIT #2 FOR CIRCUIT #1 –48A –48B RET A RET B PRINTED CIRCUIT BOARD PRINTED CIRCUIT BOARD FOR CIRCUIT #2 FOR CIRCUIT #1 1079-A BACK PLANE Figure 3. Back Plane Page 4 © 1999, ADC Telecommunications, Inc.
  • Page 5 ADCP-61-141 • Issue 2 • May 1999 SHOWN WITH SIDE DOOR REMOVED 1080-A Figure 4. Cable Routing Page 5 © 1999, ADC Telecommunications, Inc.
  • Page 6: Customer Information And Assistance

    Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.