MASSEY FERGUSON 5400 Service Manual page 867

Hide thumbs Also See for 5400:
Table of Contents

Advertisement

TR19 : Draft sensor
Description
Location: in the bracket of the top link
- Pin 1 : Reference ground (-) input
- Pin 2 : Signal output (between 2.5 V & 7.5 V)
- Pin 3 : 9.5 V reference voltage input
Possible error code
Error
Components
concerned
3 - 2
Draft sensor
N
: The error code dedicated to the draft sensor is
OTE
included in the minor failure category but depending on
the reason of the error the system can reacts as for a
serious failure.
Massey Ferguson 5400 - Issue 1.a
ELECTRONIC LINKAGE - Error codes
Description
Short circuit or
open circuit or
sensor disconnected or
failed
Overload on the sensor
MA-11-06014A
System reaction
Cuts power to lift
control valve solenoids
No lift arm movements
authorised
ELC operates but
diagnostics lamp
flashes
TR19
1
2
3
1
2
3
Fig. 10
Action
Stop the engine.
Correct the fault.
Restart the engine.
Reset the system
Correct the fault
Reset the system