MASSEY FERGUSON 5400 Service Manual page 861

Hide thumbs Also See for 5400:
Table of Contents

Advertisement

CAB4 : Height/depth adjustment potentio-
meter
Description
Location: in the ELC mouse on the right-hand side
panel in the cab.
- Pin 1 : 9.5 V reference voltage input
- Pin 2 : Signal output (between 1.6 V & 9.5 V)
- Pin 3 : 1.6 V reference voltage input
FAI73: ELC harness
Description
Location: inside the right-hand side panel in the cab.
- Resistor R30 on signal line between pin 2 of
height/depth adjustment potentiometer and pin 16
of calculator EHRB
Possible error code
Error
Components concerned
Height/depth adjustment
potentiometer
2 - 3
ELC harness
Massey Ferguson 5400 - Issue 1.a
ELECTRONIC LINKAGE - Error codes
Description
Open circuit or
potentiometer disconnected or
ELC harness resistor R30 failed
4K7
1
3
2
CAB04
1 2
3
MA-11-06010A
System reaction
ELC console locked
3
2
1
Fig. 4
Action
Correct the fault
Reset the system
11C13.9