MASSEY FERGUSON 5400 Service Manual page 859

Hide thumbs Also See for 5400:
Table of Contents

Advertisement

CAB2 : Console potentiometers:
- High position potentiometer
- Lowering speed potentiometer
- Function selector potentiometer (Draft / Intermix /
Position)
Description
Location: on the right-hand side panel inside the cab
Pin
Function selector potentiometer (Draft /
1
Intermix / Position) signal output (between
1.6 V & 9.5 V)
2
9.5 V reference voltage input
3
1.6 v minimum reference voltage input
Lowering speed potentiometer signal
4
output (between 1.6 V & 9.5 V)
High position potentiometer signal output
5
(between 1.6 V & 9.5 V)
Console status and error code indicator light
6
12 V input
7
Not used
Active Transport Control indicator light 12 V
8
input
Active Transport Control switch signal
9
output (9.5 V)
10
Lift solenoid valve indicator light 12 V input
Lower solenoid valve indicator light 12 V
11
input
12
Ground (-)
13
Not used
14
Not used
15
Not used
16
Not used
Massey Ferguson 5400 - Issue 1.a
Description
ELECTRONIC LINKAGE - Error codes
MA-11-06008A
75R
MAX
4K7
MIN
75R
4K7
75R
4K7
MAX
MIN
14
6
10
13
5
16
9
2
4
12
15
8
1
3
11
7
MA-11-06009A
R2
150R
560R
75R
R1
15R
CAB02
1 2
3 4 5 6 7 8 9 10 11 12 13 14 15 16
Fig. 2
1N4001
1N4001
560R
Fig. 3
11C13.7

Advertisement

Chapters

Table of Contents
loading

Table of Contents